Kang Bun-Jung, Ha Yong-Chan, Ham Dae-Woong, Hwang Sun-Chul, Lee Young-Kyun, Koo Kyung-Hoi
Department of Orthopaedic Surgery, Gyeongsang National University School of Medicine, Jinju, South Korea.
Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, Seoul, South Korea.
J Arthroplasty. 2015 Mar;30(3):411-5. doi: 10.1016/j.arth.2014.09.020. Epub 2014 Oct 2.
Ceramic-on-ceramic articulation has the lowest wear with little osteolysis. However, the wear and osteolysis in long-term follow-up are not known. Another concern is ceramic fracture, which might occur after repeated stress during a long period. Ninety hips (76 patients with a mean age of 47 years) that underwent cementless total hip arthroplasty using third-generation ceramic-on-ceramic articulation were followed for 14-16 years. At final follow-up, there was no measurable ceramic wear and no periprosthetic osteolysis was identified. No ceramic fracture occurred during the follow-up. One hip was revised because of late infection. All prostheses were bone-ingrown. Two patients experienced a grinding sensation. However, no patient had squeak. The mean Harris hip score at the final evaluation was 89 points and the survival rate was 98.9%.