School of Allied Health Sciences, Griffith University, Gold Coast, Queensland, Australia.
Center for Exercise and Sports Science Research, School of Medical and Health Sciences, Edith Cowan University, Perth, Australia.
J Strength Cond Res. 2022 Sep 1;36(9):2465-2471. doi: 10.1519/JSC.0000000000003872. Epub 2021 Jan 22.
Gonçalves, BM, Mesquita, RNO, Tavares, F, Brito, J, Correia, P, Santos, P, and Mil-Homens, P. A new portable device to reliably measure maximal strength and rate of force development of hip adduction and abduction. J Strength Cond Res 36(9): 2465-2471, 2022-Groin injuries are a major issue in sports involving kicking or quick changes of direction. Decreased hip adduction and abduction strength have been indicated as one of the main risk factors for groin injury. The methods currently available to measure hip adduction and abduction strength are reliable but highly dependent on the evaluator skills. Furthermore, several studies have reported the reliability of maximal strength (MVIC), but very few studies investigated the reliability of explosive strength (RFD), a parameter that has been previously shown to have a higher functional value. The aim of the current investigation was to assess the reliability of a user-independent portable dynamometer that concurrently measures MVIC and RFD. Twenty-five healthy young subjects performed maximal isometric hip adduction and abduction in both sitting and supine positions. Measurements occurred in 2 different days separated by 48-72 hours. Test-retest reliability was calculated for both MVIC and RFD. Both MVIC and RFD showed good relative reliability (intraclass correlation coefficient = 0.77-0.98) with no differences between positions or muscle actions. Measurement error was similar between positions for MVIC in both hip adduction and abduction. Measurements of RFD showed higher reliability using a time window of at least 0-100 milliseconds, and lower measurement error was observed in sitting for adduction and in supine for abduction. This study shows that portable dynamometry can be used to concurrently measure hip adduction and abduction maximal and explosive strength, with levels of reliability that are similar to previously described methods.
冈萨尔维斯,BM,梅斯基塔,RNO,塔瓦雷斯,F,布里托,J,科雷亚,P,桑托斯,P,米尔-霍门斯,P。一种新的便携式设备,可可靠地测量髋关节内收和外展的最大力量和力量发展速率。J 力量与调理研究 36(9):2465-2471,2022-腹股沟受伤是涉及踢腿或快速变向的运动中的一个主要问题。髋关节内收和外展力量的下降已被认为是腹股沟受伤的主要危险因素之一。目前用于测量髋关节内收和外展力量的方法是可靠的,但高度依赖于评估者的技能。此外,几项研究报告了最大力量(MVIC)的可靠性,但很少有研究调查爆发力(RFD)的可靠性,RFD 是一个先前被证明具有更高功能价值的参数。本研究旨在评估一种用户独立的便携式测力计的可靠性,该测力计可同时测量 MVIC 和 RFD。25 名健康的年轻受试者分别在坐姿和仰卧位下进行最大等长髋关节内收和外展运动。测量在 2 个不同的日子进行,间隔 48-72 小时。计算了 MVIC 和 RFD 的测试-重测可靠性。MVIC 和 RFD 的相对可靠性均较好(组内相关系数=0.77-0.98),位置或肌肉动作之间无差异。髋关节内收和外展的 MVIC 测量中,位置之间的测量误差相似。RFD 的测量使用至少 0-100 毫秒的时间窗口时,可靠性更高,在坐姿下进行内收测量和在仰卧位下进行外展测量时,测量误差更低。本研究表明,便携式测力计可用于同时测量髋关节内收和外展的最大力量和爆发力,其可靠性水平与先前描述的方法相似。