眼外肌运动和摩擦对植入眼压传感器的青光眼患者遥测眼压的影响。

Effect of eyelid muscle action and rubbing on telemetrically obtained intraocular pressure in patients with glaucoma with an IOP sensor implant.

机构信息

Department of Ophthalmology, Otto von Guericke University, Magdeburg, Germany.

Department of Ophthalmology, University Medical Centre Groningen, Groningen, The Netherlands.

出版信息

Br J Ophthalmol. 2023 Oct;107(10):1425-1431. doi: 10.1136/bjophthalmol-2021-320508. Epub 2022 Jun 14.


DOI:10.1136/bjophthalmol-2021-320508
PMID:35701079
原文链接:https://pmc.ncbi.nlm.nih.gov/articles/PMC10579178/
Abstract

BACKGROUND: Patients with glaucoma on topical glaucoma medication are often affected by dry eye symptoms and thus likely to rub or squeeze their eyelids. Here, we telemetrically measure peak intraocular pressure (IOP) during eyelid manoeuvres and eyelid rubbing. METHODS: Eleven patients with primary open-angle glaucoma (POAG) previously implanted with a telemetric IOP sensor (Eyemate-IO) were instructed to look straight ahead for 1 min as a baseline measurement. Next, 6 repeats of blinking on instruction with 10 s intervals in between were performed. In addition, 5 repeats of eyelid closure (n=9), eyelid squeezing and eyelid rubbing (n=7) were performed with 15 s intervals in between. IOP was recorded via an external antenna placed around the study eye. Average peak IOP increases from baseline were analysed and tested against zero (no change) with one-sample t-tests. RESULTS: For eyelid rubbing, the average peak ∆ IOP increase (mean±SEM) was 59.1±9.6 mm Hg (p<0.001) from baseline. It was 42.2±5.8 mm Hg (p<0.0001) for eyelid squeezing, 3.8±0.6 mm Hg (n=9, p<0.01) for eyelid closure and 11.6±2.4 mm Hg (p<0.001) for voluntary blinking. No IOP change except for a short irregularity in the ocular pulse was observed during involuntary blinking. CONCLUSION: Eyelid manoeuvres in patients with POAG elicited brief increases in IOP that were particularly large with squeezing and rubbing. Further investigation of the potential implications for glaucoma progression is warranted.

摘要

背景:接受局部青光眼药物治疗的青光眼患者常受干眼症症状影响,从而可能揉搓或挤压其眼睑。在此,我们通过遥测技术测量眼睑动作和眼睑摩擦期间的眼内压(IOP)峰值。

方法:11 名先前植入遥测 IOP 传感器(Eyemate-IO)的原发性开角型青光眼(POAG)患者被指示直视 1 分钟作为基线测量。接下来,每 10 秒指示重复眨眼 6 次。此外,在 15 秒间隔之间进行 5 次眼睑闭合(n=9)、眼睑挤压和眼睑摩擦(n=7)。IOP 通过放置在研究眼周围的外部天线进行记录。通过单样本 t 检验分析并针对零(无变化)测试从基线开始的平均峰值 IOP 增加量。

结果:对于眼睑摩擦,平均峰值 ∆IOP 增加量(平均值±SEM)为 59.1±9.6 mmHg(p<0.001),与基线相比。眼睑挤压为 42.2±5.8 mmHg(p<0.0001),眼睑闭合为 3.8±0.6 mmHg(n=9,p<0.01),自愿眨眼为 11.6±2.4 mmHg(p<0.001)。除了眼球脉冲的短暂不规则外,在非自愿眨眼期间未观察到 IOP 变化。

结论:POAG 患者的眼睑动作会引起短暂的 IOP 升高,特别是在挤压和摩擦时升高幅度较大。进一步研究这种变化对青光眼进展的潜在影响是必要的。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/77ee/10579178/93bee426793b/bjophthalmol-2021-320508f02.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/77ee/10579178/7df250f540d3/bjophthalmol-2021-320508f01.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/77ee/10579178/93bee426793b/bjophthalmol-2021-320508f02.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/77ee/10579178/7df250f540d3/bjophthalmol-2021-320508f01.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/77ee/10579178/93bee426793b/bjophthalmol-2021-320508f02.jpg

相似文献

[1]
Effect of eyelid muscle action and rubbing on telemetrically obtained intraocular pressure in patients with glaucoma with an IOP sensor implant.

Br J Ophthalmol. 2023-10

[2]
Implanted Microsensor Continuous IOP Telemetry Suggests Gaze and Eyelid Closure Effects on IOP-A Preliminary Study.

Invest Ophthalmol Vis Sci. 2021-5-3

[3]
Contralateral Forced Eyelid Closure Increases Intraocular Pressure.

Eye Contact Lens. 2022-7-1

[4]
Telemetric Intraocular Pressure Monitoring after Boston Keratoprosthesis Surgery Using the Eyemate-IO Sensor: Dynamics in the First Year.

Am J Ophthalmol. 2019-3-5

[5]
Attempted eyelid closure affects intraocular pressure measurement in open-angle glaucoma patients.

Am J Ophthalmol. 2002-8

[6]
Telemetric Measurement of Intraocular Pressure via an Implantable Pressure Sensor-12-Month Results from the ARGOS-02 Trial.

Am J Ophthalmol. 2019-9-20

[7]
The Effect of an Eyelid Speculum on Intraocular Pressure Measurement in Newborns.

J Pediatr Ophthalmol Strabismus. 2022

[8]
[A comparison study of pulsitile ocular blood flow in normal eyes and primary open angle glaucoma].

Zhonghua Yan Ke Za Zhi. 2004-4

[9]
[Study on changes of intraocular pressure within 24 hours in primary open angle glaucoma and normal eyes].

Zhonghua Yi Xue Za Zhi. 2011-2-22

[10]
Intraocular pressure and diurnal fluctuation of open-angle glaucoma and ocular hypertension: a baseline report from the LiGHT China trial cohort.

Br J Ophthalmol. 2023-6

引用本文的文献

[1]
Reproducibility of consecutive automated telemetric noctodiurnal IOP profiles as determined by an intraocular implant.

Br J Ophthalmol. 2024-10-22

[2]
Modeling meibum secretion: Alternatives for obstructive Meibomian Gland Dysfunction (MGD).

Ocul Surf. 2024-1

[3]
Advancements in Wearable and Implantable Intraocular Pressure Biosensors for Ophthalmology: A Comprehensive Review.

Micromachines (Basel). 2023-10-9

[4]
Toxicological effects of ocular acrolein exposure to eyelids in rabbits in vivo.

Exp Eye Res. 2023-9

[5]
Biomechanical homeostasis in ocular diseases: A mini-review.

Front Public Health. 2023

本文引用的文献

[1]
European Glaucoma Society Terminology and Guidelines for Glaucoma, 5th Edition.

Br J Ophthalmol. 2021-6

[2]
Implanted Microsensor Continuous IOP Telemetry Suggests Gaze and Eyelid Closure Effects on IOP-A Preliminary Study.

Invest Ophthalmol Vis Sci. 2021-5-3

[3]
Lower Eyelid Horizontal Tightening in Prostaglandin Associated Periorbitopathy.

Ophthalmic Plast Reconstr Surg.

[4]
Use of a novel telemetric sensor to study interactions of intraocular pressure and ganglion-cell function in glaucoma.

Br J Ophthalmol. 2021-5

[5]
Telemetric Measurement of Intraocular Pressure via an Implantable Pressure Sensor-12-Month Results from the ARGOS-02 Trial.

Am J Ophthalmol. 2019-9-20

[6]
Transient Intraocular Pressure Fluctuations: Source, Magnitude, Frequency, and Associated Mechanical Energy.

Invest Ophthalmol Vis Sci. 2019-6-3

[7]
Cyclic Pattern of Intraocular Pressure (IOP) and Transient IOP Fluctuations in Nonhuman Primates Measured with Continuous Wireless Telemetry.

Curr Eye Res. 2019-6-19

[8]
The Magnitude of Intraocular Pressure Elevation Associated with Eye Rubbing.

Ophthalmology. 2018-8-25

[9]
Association Between 24-Hour Intraocular Pressure Monitored With Contact Lens Sensor and Visual Field Progression in Older Adults With Glaucoma.

JAMA Ophthalmol. 2018-7-1

[10]
IOP telemetry in the nonhuman primate.

Exp Eye Res. 2015-12

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

推荐工具

医学文档翻译智能文献检索