Suppr超能文献

青光眼患者视网膜ON和OFF通路的不对称功能损害

Asymmetric Functional Impairment of ON and OFF Retinal Pathways in Glaucoma.

作者信息

Kong Alan W, Turner Marcus L, Chan Hoover, Stamper Robert L, Arnold Benjamin F, Della Santina Luca, Ou Yvonne

机构信息

Department of Ophthalmology, University of California, San Francisco, San Francisco, California.

Francis I. Proctor Foundation, University of California, San Francisco, San Francisco, California.

出版信息

Ophthalmol Sci. 2021 Jun;1(2). doi: 10.1016/j.xops.2021.100026. Epub 2021 May 10.

Abstract

PURPOSE

To investigate ON-pathway versus OFF-pathway dysfunction in glaucoma using handheld electroretinography (ERG) with a temporally modulated sinusoidal flicker stimulus.

DESIGN

Cross-sectional study.

PARTICIPANTS

Fifty-nine participants accounting for 104 eyes, comprised of 19 control eyes, 26 glaucoma suspect eyes, and 59 glaucoma eyes.

METHODS

Participants underwent portable ERG testing, which included the photopic flash, photopic flicker, photopic negative response stimulus, ON-OFF stimulus, and a custom-written sinusoidal flicker stimulus that was modulated from 50 to 0.3 Hz.

MAIN OUTCOME AND MEASURES

The ERG response amplitudes were measured by the handheld ERG. For the custom-written sinusoidal flicker stimulus, we derived and compared the log10 first harmonic frequency response amplitudes. Patient discomfort and fatigue after ERG testing were rated on a scale from 1 to 5.

RESULTS

Baseline demographics were not significantly different between groups, except for ocular characteristics. Analysis was performed adjusting for participant age, sex, race, and dilation status, and the sinusoidal frequency responses were stratified at 10 Hz because higher frequencies are associated with the OFF-pathway, whereas lower frequencies are associated with the ON-pathway. After stratification, glaucoma eyes showed an adjusted decrease of 32.1% at frequencies of more than 10 Hz (95% confidence interval [CI], -51.8% to -4.1%; = 0.03). For 10 Hz stimulus frequencies or less, an adjusted 11.5% reduction was found (95% CI, -39.5% to 29.1%; = 0.50). Glaucoma suspect eyes did show a decreased response, but this was not significant at either frequency range. When comparing handheld ERG with traditional visual field assessments, participants found the handheld ERG to result in much less discomfort and fatigue.

CONCLUSIONS

Our finding that glaucoma participants showed greater decreases in ERG response at higher frequencies supports the hypothesis that the OFF-pathway may be more vulnerable in human glaucoma. Using a handheld ERG device with a sinusoidal flicker stimulus may provide an objective assessment of visual function in glaucoma.

摘要

目的

使用带有时间调制正弦闪烁刺激的手持式视网膜电图(ERG)研究青光眼患者视锥系统(ON通路)与视杆 - 双极细胞 - 神经节细胞通路(OFF通路)功能障碍情况。

设计

横断面研究。

参与者

59名参与者共104只眼睛,包括19只对照眼、26只青光眼疑似眼和59只青光眼眼。

方法

参与者接受便携式ERG测试,包括明视闪光、明视闪烁、明视负反应刺激、开 - 关刺激以及一个自定义编写的从50Hz调制到0.3Hz的正弦闪烁刺激。

主要结局指标

通过手持式ERG测量ERG反应幅度。对于自定义编写的正弦闪烁刺激,我们推导并比较了以10为底的一次谐波频率反应幅度。ERG测试后患者的不适和疲劳程度按1至5分进行评分。

结果

除眼部特征外,各组间基线人口统计学特征无显著差异。分析时对参与者的年龄、性别、种族和散瞳状态进行了校正,正弦频率反应在10Hz处进行分层,因为较高频率与OFF通路相关,而较低频率与ON通路相关。分层后,青光眼眼在频率高于10Hz时调整后下降了32.1%(95%置信区间[CI],-51.8%至-4.1%;P = 0.03)。对于10Hz及以下的刺激频率,调整后下降了11.5%(95%CI,-39.5%至29.1%;P = 0.50)。青光眼疑似眼确实显示反应下降,但在两个频率范围内均无统计学意义。当将手持式ERG与传统视野评估进行比较时,参与者发现手持式ERG导致的不适和疲劳要少得多。

结论

我们的研究发现,青光眼患者在较高频率下ERG反应下降更明显,这支持了OFF通路在人类青光眼中可能更易受损的假说。使用带有正弦闪烁刺激的手持式ERG设备可能为青光眼患者的视觉功能提供客观评估。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3c6f/9559899/8d42dffee434/gr1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验