Ahonen E, Hakumäki M, Hartikainen J, Kuikka J, Länsimies E, Nevalainen T, Tahvanainen K
Scand J Clin Lab Invest. 1987 Feb;47(1):75-81.
Trained, chronically instrumented, conscious dogs were used to study the function of the left ventricle by first-pass radionuclide ventriculography (RNV). Six dogs were trained prior to a sterile left thoracotomy, where a left atrial catheter was implanted. After recovery of four days RNV was carried out by injecting a bolus of technetium-99m-DTPA via the catheter to the left atrium. The data was collected for 12 s to a computer by frame rate of 20 frames/s from left lateral view of the dog. The experiments were performed both in four-leg standing and in 60 degrees head-up tilted positions. The measurements were done with two injection volumes (0.25 and 1.0 ml/kg) to study the effect of volume on the results. The body position had effect on left ventricular end-diastolic and stroke volumes, whereas ejection fraction remained unchanged. In comparison of the two injection volumes a minor difference was found in left atrial emptying, while the differences in left ventricular function were non-significant. In spite of training and careful standardization of experimental procedures, relatively high individual variation between animals was found in most parameters studied. The first-pass RNV method proved to be promising for measuring the left ventricular function in conscious dogs. Although the left atrium has reflectory tachycardic potential to distension, the volumes used for RNV did not affect the results. The left ventricular adaptation to head-up tilting in conscious dogs seems to consist mainly of decrease in left ventricular volume without significant effect on ejection fraction.
使用经过训练、长期植入仪器的清醒犬,通过首次通过放射性核素心室造影(RNV)来研究左心室功能。六只犬在无菌左胸廓切开术前接受训练,术中植入左心房导管。恢复四天后,通过经导管向左心房注射一剂锝-99m-DTPA进行RNV。以20帧/秒的帧率从犬的左侧视图采集12秒的数据到计算机。实验分别在四腿站立和头高位倾斜60度的姿势下进行。使用两种注射体积(0.25和1.0毫升/千克)进行测量,以研究体积对结果的影响。体位对左心室舒张末期容积和每搏量有影响,而射血分数保持不变。比较两种注射体积时,发现左心房排空存在微小差异,而左心室功能的差异无统计学意义。尽管对实验程序进行了训练和仔细的标准化,但在所研究的大多数参数中,动物之间仍存在相对较高的个体差异。首次通过RNV方法被证明在测量清醒犬的左心室功能方面很有前景。尽管左心房对扩张有反射性心动过速的潜力,但用于RNV的体积并未影响结果。清醒犬左心室对头高位倾斜的适应似乎主要包括左心室容积的减少,而对射血分数无显著影响。