Suppr超能文献

利用 MRI 对神经孔狭窄进行自动分级系统的文献综述。

Literature Review of Automated Grading Systems Utilizing MRI for Neuroforaminal Stenosis.

机构信息

Department of Neurosurgery, Leeds General Infirmary, Leeds, UK.

Department of Neuroradiology, Leeds General Infirmary, Leeds, UK.

出版信息

Curr Med Imaging. 2023;19(8):874-884. doi: 10.2174/1573405618666220628100928.

Abstract

BACKGROUND

Cervical neural foraminal stenosis is a common and debilitating condition affecting people between the ages 40-60. Although it is established that MRI is the best method of scanning the neural foramen, the question remains whether there is a role for three-dimensional MRIs and whether it is possible to develop a computer-aided automated grading system to establish the degree of clinically relevant cervical foraminal stenosis.

OBJECTIVE

The study's objective is to conduct a literature review of existing or recently developed automated grading systems for the cervical neural foramen, including volumetric MRI evaluations of the foramen.

METHODS

A systematic search of Cochrane Library, Cochrane Clinical Trials, Ovid MEDLINE, EMBASE, CINAHL, ACM Digital Library and Institute of Electrical and Electronics Engineers (IEEE), and Web of Science was performed for reports examining automated systems and volumetric scanning foraminal stenosis published before 31.07.2021.

RESULTS

3971 articles were identified of which 8 were included in the study. The automated grading systems of the neural foramen focus largely on the lumbar spine with elements that may be applicable to the cervical spine. Although there are established studies on the automated grading of the lumbar spine, it is uncertain whether any of these are reproducible in the cervical spine. Visual grading systems for the cervical spine demonstrate good inter-reader reliability between radiologists and clinicians.

CONCLUSION

The Park visual grading method shows strong inter-reader reliability across radiologists and clinicians despite the limited data on the correlation with neurological symptoms or surgical outcome. There is scope for further development of an automated grading system for cervical foraminal stenosis to improve the speed and consistency of image interpretation.

摘要

背景

颈椎神经孔狭窄症是一种常见且使人虚弱的疾病,影响 40-60 岁之间的人群。尽管已经确定 MRI 是扫描神经孔的最佳方法,但仍存在三维 MRI 是否有作用的问题,以及是否有可能开发计算机辅助自动分级系统来确定具有临床相关性的颈椎神经孔狭窄程度。

目的

本研究的目的是对现有的或最近开发的颈椎神经孔自动分级系统进行文献回顾,包括对神经孔的容积 MRI 评估。

方法

对 Cochrane 图书馆、Cochrane 临床试验、Ovid MEDLINE、EMBASE、CINAHL、ACM 数字图书馆和电气和电子工程师协会 (IEEE) 和 Web of Science 进行了系统搜索,以检索审查自动系统和容积扫描神经孔狭窄的报告,这些报告发表于 2021 年 7 月 31 日之前。

结果

共确定了 3971 篇文章,其中 8 篇被纳入研究。神经孔的自动分级系统主要集中在腰椎,其中有一些可能适用于颈椎。虽然已经有关于腰椎自动分级的既定研究,但尚不确定这些研究是否可以在颈椎中复制。颈椎的视觉分级系统显示出放射科医生和临床医生之间良好的读者间可靠性。

结论

尽管与神经症状或手术结果的相关性数据有限,但 Park 视觉分级方法在放射科医生和临床医生之间显示出很强的读者间可靠性。有进一步开发颈椎神经孔狭窄自动分级系统的空间,以提高图像解释的速度和一致性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验