INTRODUCTION/AIMS: Ultrasonography of the cranial nerves has recently gained attention for assessment of inflammatory, compressive, or degenerative neuropathies. However, sonographic reference values of cranial nerves have received less attention than those of peripheral nerves. In this systematic review and meta-analysis we aimed to provide current evidence of sonographic reference values for cranial nerve size.
By searching Medline (via PubMed), Scopus, Embase, Cochrane Central Register of Controlled Trials (CENTRAL), and Web of Science, we conducted a systematic review and meta-analysis of studies that reported ultrasound measurements of the facial, spinal accessory, and hypoglossal nerves in healthy adults. We included studies that reported either the sonographic cross-sectional area (CSA) or the nerve diameter; the included nerves were subgrouped according to the site of nerve measurement.
Fourteen studies with a total of 661 participants and 1437 ultrasound nerve measurements met the inclusion criteria. The anatomical sites for each nerve were combined to provide single-nerve mean measurements. We found an overall mean nerve diameter of 0.80 mm for the facial nerve, 0.63 mm for the spinal accessory nerve, and 1.82 mm for hypoglossal nerve CSA.
This meta-analysis provides reference values for the diameter and cross-sectional area of the facial, spinal accessory, and hypoglossal nerves at different sites, which can be used as guidance in clinical practice to detect pathological changes in cranial nerve size in cranial neuropathies. We recommend further validation in large-scale studies as well as standardization of the scanning protocols.
简介/目的:颅神经超声检查最近因其对炎症、压迫或退行性神经病变的评估而受到关注。然而,颅神经的超声参考值比周围神经的参考值受到的关注更少。在这项系统评价和荟萃分析中,我们旨在提供目前关于颅神经大小的超声参考值的证据。
通过搜索 Medline(通过 PubMed)、Scopus、Embase、Cochrane 中央对照试验注册中心(CENTRAL)和 Web of Science,我们对报告健康成年人面部、副神经和舌下神经超声测量的研究进行了系统评价和荟萃分析。我们纳入了报告超声测量的横截面积(CSA)或神经直径的研究;根据神经测量部位将纳入的神经分组。
共有 14 项研究,总计 661 名参与者和 1437 次超声神经测量符合纳入标准。每个神经的解剖部位组合起来提供单一神经的平均测量值。我们发现面神经的平均神经直径为 0.80 毫米,副神经为 0.63 毫米,舌下神经 CSA 为 1.82 毫米。
这项荟萃分析提供了不同部位面神经、副神经和舌下神经的直径和 CSA 的参考值,可作为临床实践中检测颅神经病中颅神经大小病理性变化的指南。我们建议在大规模研究中进一步验证,并标准化扫描方案。