Suppr超能文献

腕关节 X 线片与三维成像中桡尺骨和腕骨对线测量的可靠性。

Reliability of radio-ulnar and carpal alignment measurements in the wrist between radiographs and 3D imaging.

机构信息

Diagnostic department, Radiology Unit, Geneva University Hospital, Rue Gabrielle-Perret-Gentil 4, 1205 Genève, Switzerland.

Orthopedic and traumatology surgery department, Hand Surgery Unit, Geneva University Hospital, Rue Gabrielle-Perret-Gentil 4, 1205 Genève, Switzerland.

出版信息

Eur J Radiol. 2022 Sep;154:110417. doi: 10.1016/j.ejrad.2022.110417. Epub 2022 Jun 22.

Abstract

OBJECTIVE

Conventional radiography is the first modality to investigate the radio-ulno-carpal joint in the event of trauma or instability. This study sought to determine the reliability of cone beam computer tomography (CBCT) and scout of view in evaluating carpal alignment compared with conventional radiographs in order to assess the influence of wrist kinematics on usual measurements.

MATERIALS AND METHODS

We prospectively recruited 305 patients who successively underwent plain radiography and CBCT. 51 patients with prior acute unilateral wrist trauma were eligible for entry into the study (mean age of 39 years). Three blinded readers performed the measurements separately. The axial method and bony axial lines defined previously in the literature were applied, with three categories of measurements performed, consisting of distal radio-ulnar, radiocarpal, and radio/carpometacarpal measurements. Intraclass correlation coefficients (ICCs) for paired t-test were calculated to assess inter- and intra-observer agreements.

RESULTS

Inter-observer agreement was very high (>0.94) for all modalities. Intra-observer reliability between scout view and CBCT was almost perfect for all measurements. Intra-observer reliability between radiograph and scout view/CBCT was perfect for distal radio-ulnar measurements, substantial for radio-carpal, and moderate for radio/carpometacarpal measurements.

CONCLUSION

In the absence of a strict position control between two imaging acquisitions, only distal radio-ulnar measurements were shown perfectly reliable when using these two imaging methods, which is suggestive of a minor relevance of ulnar/radial deviation. Excepting for some angles, the radio-carpal and radio-carpometacarpal measurements were shown to differ according to wrist position, being thus more sensitive to flexion/extension of the wrist.

摘要

目的

在创伤或不稳定的情况下,常规放射摄影是检查桡腕关节的首选方式。本研究旨在确定与常规放射摄影相比,锥形束计算机断层扫描(CBCT)和视窗探测在评估腕骨对线方面的可靠性,以评估腕部运动对常规测量的影响。

材料和方法

我们前瞻性地招募了 305 名连续接受普通放射摄影和 CBCT 的患者。51 名有单侧急性腕部创伤史的患者符合入组条件(平均年龄 39 岁)。三名盲法读者分别进行了测量。应用了文献中先前定义的轴向方法和骨轴向线,进行了三类测量,包括桡尺远侧、桡腕和桡/腕掌测量。计算配对 t 检验的组内相关系数(ICC),以评估观察者间和观察者内的一致性。

结果

所有模态的观察者间一致性均非常高(>0.94)。在所有测量中,视窗探测和 CBCT 之间的观察者内可靠性几乎为完美。在放射摄影和视窗探测/CBCT 之间,桡尺远侧测量的观察者内可靠性为完美,桡腕测量为实质,桡/腕掌测量为中度。

结论

在两次成像采集之间没有严格的位置控制的情况下,仅当使用这两种成像方法时,桡尺远侧测量被证明是完全可靠的,这表明尺桡偏斜的相关性较小。除了一些角度外,桡腕和桡掌测量根据腕部位置而有所不同,因此对腕部的屈伸更为敏感。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验