Measurement of Carpal Alignment Indices Using 3-Dimensional Computed Tomography.

作者信息

Lee Ki Won, Bae Joo Yul, Seo Dong-Kyo, Kim Sang Bum, Lee Hyun Il

机构信息

Department of Orthopaedic Surgery, Gangneung Asan Hospital, Ulsan University College of Medicine, Gangneung, Korea.

Department of Orthopaedic Surgery, Inje University, Ilsan Paik Hospital, Gyeonggi-do, Korea.

出版信息

J Hand Surg Am. 2018 Aug;43(8):771.e1-771.e7. doi: 10.1016/j.jhsa.2018.01.003. Epub 2018 Feb 7.

Abstract

PURPOSE

This study aimed to establish normal values for wrist carpal alignment measured by 3-dimensional computed tomography (CT) and to show the inter- and intraobserver reliability of this measurement compared with simple radiography.

METHODS

The study utilized 3-dimensional CT and simple radiography of wrist joints in 30 asymptomatic volunteers. The wrist position was standardized using a custom-designed positioning device. Three independent observers measured carpal alignment parameters including distal radius articular angle, radiolunate angle, radioscaphoid angle, radiocapitate angle, radius-third metacarpal angle, scapholunate angle, lunocapitate angle, and lunate-third metacarpal angle.

RESULTS

Based on 3-dimensional CT measurement, the mean values of these parameters were: 12.9° ± 1.8° for the distal radius articular angle; 1.2° ± 3.8° for the radiolunate angle; 54.2° ± 5.6° for the radioscaphoid angle; 1.9° ± 2.2° for the radiocapitate angle; -1.0° ± 2.5° for the radius-third metacarpal angle; 52.9° ± 6.9° for the scapholunate angle; 0.7° ± 4.1° for the lunocapitate angle; -2.3° ± 4.6° for the lunate-third metacarpal angle. All parameters showed high inter- and intraobserver reliability in the 2 modalities.

CONCLUSIONS

The normal values and ranges for carpal alignment angles were evaluated by using 3-dimensional CT. We could obtain high reliability in 3-dimensional CT as well as plain radiograph for the measurement of carpal alignment.

TYPE OF STUDY/LEVEL OF EVIDENCE: Diagnostic II.

摘要

目的

本研究旨在确定通过三维计算机断层扫描(CT)测量腕部腕骨对线的正常值,并展示该测量方法与简单X线摄影相比,在观察者间和观察者内的可靠性。

方法

本研究对30名无症状志愿者的腕关节进行了三维CT和简单X线摄影。使用定制设计的定位装置使腕部位置标准化。三名独立观察者测量了腕骨对线参数,包括桡骨远端关节角、桡月角、桡舟角、桡头角、桡骨-第三掌骨角、舟月角、月头角和月骨-第三掌骨角。

结果

基于三维CT测量,这些参数的平均值为:桡骨远端关节角12.9°±1.8°;桡月角1.2°±3.8°;桡舟角54.2°±5.6°;桡头角1.9°±2.2°;桡骨-第三掌骨角-1.0°±2.5°;舟月角52.9°±6.9°;月头角0.7°±4.1°;月骨-第三掌骨角-2.3°±4.6°。所有参数在两种模式下均显示出高观察者间和观察者内可靠性。

结论

通过三维CT评估了腕骨对线角的正常值和范围。在测量腕骨对线时,三维CT以及普通X线摄影均可获得高可靠性。

研究类型/证据水平:诊断性研究II级。