A venous microcannulation technique applied to the cat gastrocnemius muscle was developed which, based on morphological and functional demonstrations of anastomotic connections between two supplying segmental vascular circuits at the level of capillaries and/or post-capillary venules, seems to permit continuous recordings of hydrostatic pressure (denoted Pcvenule) transmitted from such anastomoses, that is, from a site close to the main fluid exchange vessels. For validity tests, such Pcvenule recordings were compared with simultaneous estimates of capillary pressure (Pc) with the isogravimetric technique (Pciso) and, further, with data for experimentally evoked changes of Pc derived from volumetric recordings of net transvascular fluid flux divided by the capillary filtration coefficient (delta Pcvol). Simultaneously obtained data for Pcvenule and Pciso showed close agreement, and the Pcvenule and Pcvol data showed a highly significant linear correlation over a wide range of Pc changes. These results indicate that reliable estimates of Pc can be obtained with the Pcvenule method. It allows for continuous Pc recordings without interfering with normal vascular reactivity and can be applied to non-isogravimetric conditions and combined with simultaneous observations of whole-organ transvascular fluid exchange. At normal arterial and venous pressures and vascular tone, Pcvenule averaged 16.2 +/- 0.2 mm Hg, at which a Starling fluid equilibrium prevailed, and increased with decreasing vascular tone, resulting in net transvascular fluid filtration.

摘要

我们开发了一种应用于猫腓肠肌的静脉微插管技术。基于在毛细血管和/或毛细血管后微静脉水平上两个供血节段性血管回路之间吻合连接的形态学和功能演示,该技术似乎能够连续记录从此类吻合处传来的静水压力(表示为Pcvenule),即从靠近主要液体交换血管的部位传来的压力。为了进行有效性测试,将此类Pcvenule记录与采用等重力技术同时估算的毛细血管压力(Pc)(Pciso)进行比较,并且进一步与通过净跨血管液体通量的体积记录除以毛细血管滤过系数得出的实验诱发的Pc变化数据(δPcvol)进行比较。同时获得的Pcvenule和Pciso数据显示出密切的一致性,并且在广泛的Pc变化范围内,Pcvenule和Pcvol数据显示出高度显著的线性相关性。这些结果表明,使用Pcvenule方法可以获得可靠的Pc估算值。它允许连续记录Pc,而不会干扰正常的血管反应性,并且可以应用于非等重力条件下,并与全器官跨血管液体交换的同步观察相结合。在正常的动脉和静脉压力以及血管张力下,Pcvenule平均为16.2±0.2 mmHg,此时存在Starling液体平衡,并且随着血管张力的降低而增加,导致跨血管液体净滤过。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验