Suppr超能文献

评估双单元陶瓷滤池去除高污染地下水中砷的配置。

Evaluating configuration of dual unit ceramic filter for arsenic removal from highly contaminated groundwater.

机构信息

Department of Civil Engineering, College of Engineering, Qassim University, Buraydah, 51452, Saudi Arabia.

Department of Civil Engineering, College of Engineering, Qassim University, Buraydah, 51452, Saudi Arabia.

出版信息

J Environ Manage. 2022 Oct 1;319:115664. doi: 10.1016/j.jenvman.2022.115664. Epub 2022 Jul 8.

Abstract

Iron (Fe) amended dual unit ceramic filters (DUCF) can be a viable treatment option for arsenic (As) removal from highly contaminated groundwater. The present field study investigated the effect of filter configurations, the separate-unit dual filter (SUDF) and connect-unit dual filter (CUDF), on As removal from groundwater having As concentration of 475 μg/L. SUDF was configured by placing 1st and 2nd filter units side-by-side, whereas the 1st filter unit was placed on the top of the 2nd filter unit in CUDF configuration. Comparing the two filter configurations, SUDF achieving As concentration in the effluent below 50 μg/L (standard value) was found more effective due to sufficient Fe in the 2nd filter. Average As concentrations in the final product (effluent of 2nd filter) were 43 μg/L from SUDF and 111 μg/L from CUDF. The short hydraulic residence time (3.3 min) in the 2nd filter of CUDF, along with limited contact between water and the iron net, lead to inadequate soluble Fe resulting in poor As removal. Both filter configurations effectively removed Fe, P, and Mn with more than 90% reduction of these parameters by the 1st filter. Analysis of insoluble hydrous ferric oxides flocs through XAFS L3-edge spectra confirmed the oxidation of As(III) to As(V) in both the SUDF and CUDF systems resulting in enhanced As removal efficiency. The study results found SUDF as an appropriate configuration for filter design to treat highly contaminated groundwater in rural areas of developing countries.

摘要

铁(Fe)改性双联陶瓷过滤器(DUCF)可作为去除高浓度受污染地下水中砷(As)的可行处理方法。本现场研究调查了过滤器配置(独立单元双联过滤器(SUDF)和连接单元双联过滤器(CUDF))对砷浓度为 475μg/L 的地下水的除砷效果。SUDF 通过并排放置第一和第二过滤单元来配置,而在 CUDF 配置中,第一过滤单元放置在第二过滤单元的顶部。与两种过滤配置相比,由于第二过滤单元中存在足够的 Fe,因此 SUDF 能够将出水的砷浓度降低至 50μg/L 以下(标准值),这更有效。来自 SUDF 的最终产品(第二过滤器的出水)中的平均砷浓度为 43μg/L,而来自 CUDF 的平均砷浓度为 111μg/L。由于 CUDF 中的第二过滤器的水力停留时间短(3.3 分钟),并且水与铁网之间的接触有限,导致可溶性 Fe 不足,从而导致除砷效果不佳。两种过滤配置都有效地去除了铁、磷和锰,第一过滤器对这些参数的去除率超过 90%。通过 XAFS L3 边缘光谱对不溶性水合氧化铁絮体的分析证实,在 SUDF 和 CUDF 系统中,As(III)都被氧化为 As(V),从而提高了除砷效率。研究结果发现,SUDF 是一种适合农村地区发展中国家处理高浓度受污染地下水的过滤器设计配置。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验