Borges A F
Plast Reconstr Surg. 1978 Oct;62(4):542-5. doi: 10.1097/00006534-197810000-00007.
A technique is presented for designing the 8 possible Limberg flaps to close any given rhomboidal defect. Then we show how to choose out of those 8 the only two that will be correctly oriented so the donor area of the Limberg flap can be closed with a minimal amount of tension.