Suppr超能文献

犬附肢骨骼肌质量评估:文献综述范围界定。

Appendicular skeletal muscle mass assessment in dogs: a scoping literature review.

机构信息

Colorado State University College of Veterinary Medicine and Biomedical Sciences, 300 W Drake Road, Fort Collins, CO, 80523, USA.

出版信息

BMC Vet Res. 2022 Jul 16;18(1):280. doi: 10.1186/s12917-022-03367-5.

Abstract

BACKGROUND

Monitoring changes in appendicular skeletal muscle mass is frequently used as a surrogate marker for limb function. The primary objective of this study was to review scientific information related to the assessment of appendicular skeletal muscle mass in dogs. The secondary objective was to develop practical recommendations for serial evaluation of muscle mass.

METHODS

A scoping review was conducted with a systematic search of PubMed, Web of Science, CAB abstract, and Cochrane from inception to June 2021. The following modalities were included in the search: limb circumference, diagnostic ultrasound, computed tomography, magnetic resonance imaging, and dual-energy x-ray absorptiometry.

RESULTS

A total of 62 articles that measured appendicular skeletal muscle mass in dogs were identified. Limb circumference (55 articles) was the most commonly used modality. Its reliability was investigated in five studies. Several factors, including measuring tape type, body position, joint angles, and the presence of hair coat, were reported as variables that can affect measurements. Diagnostic ultrasound (five articles) was validated in three articles, but there is scarce information about observer reliability and variables affecting the measurement. Computed tomography (four articles) and magnetic resonance imaging (one article) have been used to validate other modalities at a single time point rather than as a clinical tool for serial muscle mass monitoring. Dual-energy x-ray absorptiometry (two articles) has been used to quantify specific skeletal muscle mass but was mainly used to evaluate body composition in dogs.

CONCLUSION

Limb circumference and ultrasound are likely the main modalities that will continue to be used for serial muscle mass measurement in the clinical setting unless a new technology is developed. The reliability of limb circumference is questionable. Several key factors, including measuring tape type, body position, joint angles, and coat clipping, need to be controlled to improve the reliability of limb circumference measurements. Ultrasound may provide a reasonable alternative, but further studies are required to evaluate the reliability of this modality and identify factors that influence ultrasound measurements.

摘要

背景

监测四肢骨骼肌量的变化通常被用作肢体功能的替代标志物。本研究的主要目的是综述与犬四肢骨骼肌量评估相关的科学信息。次要目的是为肌肉量的连续评估制定实用建议。

方法

对从开始到 2021 年 6 月在 PubMed、Web of Science、CAB 摘要和 Cochrane 进行了系统检索,对肢围、诊断超声、计算机断层扫描、磁共振成像和双能 X 射线吸收法等进行了综述。

结果

共确定了 62 篇测量犬四肢骨骼肌量的文章。肢围(55 篇文章)是最常用的方法。有 5 项研究调查了其可靠性。有报道称,测量带类型、身体姿势、关节角度和毛发存在等因素会影响测量结果。诊断超声(5 篇文章)在 3 篇文章中得到验证,但关于观察者可靠性和影响测量的变量的信息很少。计算机断层扫描(4 篇文章)和磁共振成像(1 篇文章)曾在单个时间点用于验证其他方法,但作为连续肌肉量监测的临床工具,其信息有限。双能 X 射线吸收法(2 篇文章)已用于量化特定的骨骼肌量,但主要用于评估犬的身体成分。

结论

除非开发出新的技术,否则肢围和超声可能仍然是临床连续肌肉量测量的主要方法。肢围的可靠性值得怀疑。需要控制几个关键因素,包括测量带类型、身体姿势、关节角度和剪毛,以提高肢围测量的可靠性。超声可能是一种合理的替代方法,但需要进一步研究来评估该方法的可靠性并确定影响超声测量的因素。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/c950/9288046/805f09424a58/12917_2022_3367_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验