Suppr超能文献

第三代和第四代陶瓷对陶瓷全髋关节置换术至少随访十年。

Third and fourth generation ceramic-on-ceramic total hip arthroplasty at a minimum of ten years.

作者信息

McCarthy Cathal J, Mahon John, Sheridan Gerard A, Welch-Phillips Adanna, O'Byrne John M, Kenny Paddy J

机构信息

National Orthopaedic Hospital Cappagh, Dublin, Ireland.

Royal College of Surgeon Ireland, Dublin, Ireland.

出版信息

J Clin Orthop Trauma. 2022 Jul 6;31:101942. doi: 10.1016/j.jcot.2022.101942. eCollection 2022 Aug.

Abstract

BACKGROUND

Ceramic on Ceramic bearings in Total Hip Arthroplasty (THA) afford a low friction coefficient, low wear rates and extreme hardness. Significant complications include hip squeak, ceramic fracture and poor polyethylene performance in revision procedures due to imbedding of abrasive microscopic ceramic fragments. We report on the results of this bearing at a minimum of 10 years.

METHODS

A single-centre retrospective review of 449 THAs was performed. Primary outcome measures included aseptic revision and all-cause revision rates at a minimum of 10 years post operatively. Evaluation of functionality was performed with WOMAC and SF-36 scores which were performed pre-operatively and at intervals of 6 months, one year, 2 years, 5 years and 10 years post operatively.

RESULTS

There was a 6.2% (n = 28) all-cause and 5.3% (n = 24) aseptic revision rate for ceramic on ceramic total hip arthroplasty at minimum of 10 years with a mean time to revision 4.8 years (range 2 months-11.6 years). Notably, there were 2 revisions for ceramic head fracture, one for ceramic liner fracture, 3 for aseptic loosening and 3 revisions for squeaking. Pain of unknown origin was the most common reason for revision. There was an improvement in postoperative WOMAC scores from a mean of 59.8 (range 15-95) pre-operatively to a mean of 15.6 (range 0-78) at 10 years.

CONCLUSION

This study showed good functional outcomes but high revision rates for CoC THA at a minimum of 10 years. Our rates of ceramic fracture were consistent with other studies.

摘要

背景

全髋关节置换术(THA)中使用的陶瓷对陶瓷轴承具有低摩擦系数、低磨损率和极高的硬度。其显著并发症包括髋关节摩擦音、陶瓷骨折以及在翻修手术中因微小陶瓷磨粒嵌入导致的聚乙烯性能不佳。我们报告了该轴承至少10年的使用结果。

方法

对449例全髋关节置换术进行了单中心回顾性研究。主要观察指标包括术后至少10年的无菌性翻修率和全因翻修率。通过WOMAC和SF - 36评分对功能进行评估,术前以及术后6个月、1年、2年、5年和10年进行评分。

结果

陶瓷对陶瓷全髋关节置换术至少10年时的全因翻修率为6.2%(n = 28),无菌性翻修率为5.3%(n = 24),平均翻修时间为4.8年(范围2个月 - 11.6年)。值得注意的是,有2例因陶瓷股骨头骨折翻修,1例因陶瓷内衬骨折翻修,3例因无菌性松动翻修,3例因摩擦音翻修。不明原因疼痛是最常见的翻修原因。术后WOMAC评分从术前平均59.8(范围15 - 95)改善至10年时的平均15.6(范围0 - 78)。

结论

本研究表明,陶瓷对陶瓷全髋关节置换术至少10年时功能结果良好,但翻修率较高。我们的陶瓷骨折发生率与其他研究一致。

相似文献

3
Ceramic-on-Ceramic in Total Hip Replacement Revision.全髋关节置换翻修术中的陶瓷对陶瓷
Z Orthop Unfall. 2018 Jun;156(3):272-280. doi: 10.1055/s-0043-124767. Epub 2018 Feb 27.

本文引用的文献

4
Ceramic-on-ceramic bearings total hip arthroplasty in young patients.年轻患者的陶瓷对陶瓷轴承全髋关节置换术
Arthroplast Today. 2016 Aug 25;2(4):205-209. doi: 10.1016/j.artd.2016.04.004. eCollection 2016 Dec.
9
Midterm Results of Delta Ceramic-on-Ceramic Total Hip Arthroplasty.德尔塔陶瓷对陶瓷全髋关节置换术的中期结果
J Arthroplasty. 2015 Sep;30(9 Suppl):110-5. doi: 10.1016/j.arth.2015.02.047. Epub 2015 Jun 3.