Suppr超能文献

使用三维光学轮廓仪测量角膜屈光手术中的角膜基质脱水和最佳基质暴露时间。

Corneal stromal dehydration and optimal stromal exposure time during corneal refractive surgery measured using a three-dimensional optical profiler.

机构信息

Tianjin Eye Institute, Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin Eye Hospital, No 4. Gansu Road, He-ping District, Tianjin, 300020, China.

Nankai University Affiliated Eye Hospital, Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China.

出版信息

Graefes Arch Clin Exp Ophthalmol. 2022 Dec;260(12):4005-4013. doi: 10.1007/s00417-022-05764-w. Epub 2022 Jul 25.

Abstract

PURPOSE

To quantitatively analyze human corneal stromal dehydration and estimate proper corneal stromal exposure time during corneal refractive surgery.

METHODS

The central thickness changes over time in 34 pieces of human corneal tissue were measured using a white light interferometer. The corneal stromal tissue was obtained by femtosecond laser small incision lenticule extraction. The thickness-time dehydration fitting curves were drawn, and the determination coefficient R was calculated. The differences in the fitting curve equation coefficients were compared between the thin and thick lenticule groups. The optimal stromal exposure time was calculated under various conditions, including different optical zones and allowable refractive errors.

RESULTS

A water loss variation model was successfully established. Linear and quadratic fitting curves were drawn, and the determination coefficient R values were significantly close to 1. The average values of R for quadratic curves and linear phases 1, 2, and 3 were 0.998 ± 0.002, 0.995 ± 0.007, 0.996 ± 0.003, and 0.984 ± 0.035, respectively. The optimal stromal exposure time varied under different optical zones and allowable diopter error conditions. Taking the allowable error of 0.50 D and the optical zone size of 6.5 mm as an example, the optimal time was approximately 24 s.

CONCLUSIONS

The dehydration rate of the human corneal stroma is nonlinear, and the quadratic stromal thickness-time dehydration fitting curve is more in line with the actual water loss trend. The length of the stroma exposure time may affect the postoperative refractive accuracy after corneal refractive surgery.

摘要

目的

定量分析人眼角膜基质脱水情况,并估算角膜屈光手术中适当的角膜基质暴露时间。

方法

使用白光干涉仪测量 34 个人眼角膜组织的随时间变化的中心厚度。通过飞秒激光小切口透镜提取术获得角膜基质组织。绘制角膜基质组织厚度-时间脱水拟合曲线,并计算决定系数 R。比较薄透镜组和厚透镜组拟合曲线方程系数的差异。在不同条件下(包括不同光学区和允许的屈光误差)计算最佳基质暴露时间。

结果

成功建立了一个水分流失变化模型。绘制了线性和二次拟合曲线,决定系数 R 值非常接近 1。二次曲线和线性阶段 1、2 和 3 的平均 R 值分别为 0.998±0.002、0.995±0.007、0.996±0.003 和 0.984±0.035。在不同光学区和允许屈光度误差条件下,最佳基质暴露时间会发生变化。以允许误差为 0.50 D 和光学区尺寸为 6.5 mm 为例,最佳时间约为 24 s。

结论

人眼角膜基质脱水率是非线性的,二次角膜基质厚度-时间脱水拟合曲线更符合实际失水趋势。基质暴露时间的长短可能会影响角膜屈光手术后的术后屈光精度。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验