Suppr超能文献

眼轴长度对黄斑中心凹基底膜开口距离在光学相干断层扫描中的影响。

The effect of axial length to basement-membrane opening to fovea distance on optical coherence tomography.

作者信息

Dersch Anne M, Stucker Kathryn L, Hajrasouliha Amir R

机构信息

Department of Ophthalmology, Eugene and Marilyn Glick Eye Institute, 12250Indiana University School of Medicine, Indianapolis, IN, USA.

出版信息

Eur J Ophthalmol. 2023 Jan;33(1):463-467. doi: 10.1177/11206721221116699. Epub 2022 Jul 25.

Abstract

BACKGROUND

Optical Coherence Tomography (OCT) lateral scaling is influenced by axial length (AL). There is a need to incorporate a method to correct this measurement bias for accurate lateral OCT measurement.

PURPOSE

To identify the correlation of optic-nerve-to-fovea distance measurement to AL by OCT) as an internal factor for lateral scaling.

METHODS

Using Heidelberg Spectralis OCT, distance from the basement membrane opening at the optic disc margin to the centre of the fovea (BMO-fovea distance) was measured in 135 eyes (77 subjects, ages 25-85). These measurements were correlated with AL measurements from Zeiss IOLMaster 700 using linear regression before and after correction for ocular magnification. Statistical analysis including Shapiro-Wilk test for normality, Pearson correlation, and multivariate analysis of the association between disc-fovea distance and AL was performed using Wizard statistical software for mac.

RESULTS

After lateral scaling, the mean distance between the fovea and BMO was 3.60 ± 0.25 mm (median: 3.59; range 3.07-4.23 mm). There was a significant positive correlation between AL and Bennett's formula-corrected BMO-fovea distance (p <0.001, r = 0.354).

CONCLUSIONS

While there is significant variability in BMO-fovea distances, it is positively correlated with AL. A standard method is needed to improve the lateral scaling measurements in order to unify the results for enface OCT imaging.

摘要

背景

光学相干断层扫描(OCT)横向缩放受眼轴长度(AL)影响。需要纳入一种方法来校正这种测量偏差,以进行准确的OCT横向测量。

目的

确定通过OCT测量的视神经至黄斑中心距离与AL之间的相关性,作为横向缩放的内部因素。

方法

使用海德堡谱域OCT,在135只眼(77名受试者,年龄25 - 85岁)中测量从视盘边缘的基底膜开口到黄斑中心的距离(BMO-黄斑距离)。在对眼放大率进行校正前后,使用线性回归将这些测量值与蔡司IOLMaster 700测量的AL值相关联。使用适用于Mac的Wizard统计软件进行统计分析,包括用于正态性的夏皮罗-威尔克检验、皮尔逊相关性以及视盘-黄斑距离与AL之间关联的多变量分析。

结果

横向缩放后,黄斑与BMO之间的平均距离为3.60±0.25 mm(中位数:3.59;范围3.07 - 4.23 mm)。AL与经贝内特公式校正的BMO-黄斑距离之间存在显著正相关(p <0.001,r = 0.354)。

结论

虽然BMO-黄斑距离存在显著变异性,但它与AL呈正相关。需要一种标准方法来改进横向缩放测量,以便统一OCT表面成像的结果。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验