Furka I, Mikó I, Szabó Z, Hajdu J, Pintér J
Acta Chir Hung. 1986;27(4):217-21.
The temperature values obtained in renal hypothermia through the venous circulation were biometrically analysed. It was found that there could be even about 4 degrees C temperature differences between the lower and upper poles of the kidney, always as large as 4 degrees C could be elicited in the first five minutes of hypothermia, the lower pole being colder. Similar but smaller differences were observed in ten minutes' hypothermia.
对通过静脉循环进行肾脏低温灌注时获得的温度值进行了生物统计学分析。结果发现,肾脏上下极之间的温度差异甚至可能达到约4摄氏度,在低温灌注的前五分钟内总能引发高达4摄氏度的差异,下极温度更低。在十分钟的低温灌注中观察到了类似但较小的差异。