Suppr超能文献

辐照照度和曝光时间对牙本质通用粘结剂的机械和粘结性能的影响。

Influence of Irradiance and Exposure Times on the Mechanical and Adhesive Properties of Universal Adhesives with Dentin.

机构信息

Andres Felipe Millan Cardenas, DDS, Ms, PhD, professor, Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil.

Fabiana Suelen Figuerêdo de Siqueira, DDS, Ms, PhD, professor, Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil.

出版信息

Oper Dent. 2022 Jul 1;47(4):412-424. doi: 10.2341/21-042-L.

Abstract

OBJECTIVES

This study evaluated the influence of irradiance/exposure time on the Knoop hardness (KHN) and polymer cross-linking density (PCLD), as well as microtensile bond strength (μTBS), nanoleakage (NL), and in situ degree of conversion (DC) of universal adhesives.

METHODS AND MATERIALS

Two universal adhesive systems, Clearfil Universal Bond Quick (CUQ) and Scotchbond Universal Adhesive (SBU), were light-cured using various irradiance/exposure times: 1400 mW/cm2 for 5 s (14005); 1400 mW/cm2 for 10 s (140010); 3200 mW/cm2 for 5 s (32005); and 3200 mW/cm2 for 10 s (320010). Adhesive disks from each group were used to measure PCLD by KHN. One hundred and twenty-eight human molars were randomly assigned to 16 groups according to the following variables: adhesive system vs adhesive strategies vs radiance/exposure times. After restoration, specimens were sectioned into resin-dentin sticks and tested for μTBS, NL, and DC. The data from PCLD (%), KHN, μTBS (MPa), NL (%), and DC (%) data were subjected to ANOVA and Tukey's test (α=0.05).

RESULTS

Significant reductions in KHN, μTBS, and DC (p=0.00001) values and an increase in NL and PCLD (p=0.00001) values were observed for 320010 when compared with other groups. Higher KHN, μTBS, and DC (p=0.000001) values were observed for 32005 in comparison with the other groups. The 14005 (7 J/cm2) and 140010 (14 J/cm2) groups showed intermediate values (p=0.000001).

CONCLUSION

Although similar results in terms of hardness, polymer cross-linking density and nanoleakage were observed when 5 seconds at 3200 mW/cm2 and 10 seconds at 1400 mW/cm2 groups were compared, the use of higher irradiance (3200 mW/cm2) for only 5 seconds showed better results in terms of bond strength and degree of conversion for both universal adhesives to dentin. The prolonged exposure time (10 seconds) at the higher irradiance (3200 mW/cm2) showed the worst results.

摘要

目的

本研究评估辐照度/暴露时间对通用型胶粘剂的努氏硬度(KHN)和聚合物交联密度(PCLD)、微拉伸粘结强度(μTBS)、纳米渗漏(NL)和原位转化率(DC)的影响。

方法与材料

使用不同的辐照度/暴露时间对两种通用型胶粘剂系统 Clearfil Universal Bond Quick(CUQ)和 Scotchbond Universal Adhesive(SBU)进行光固化:1400 mW/cm2 5 秒(14005);1400 mW/cm2 10 秒(140010);3200 mW/cm2 5 秒(32005);3200 mW/cm2 10 秒(320010)。每组的胶粘剂圆盘用于通过 KHN 测量 PCLD。将 128 个人类磨牙随机分为 16 组,根据以下变量:胶粘剂系统对胶粘剂策略对辐照度/暴露时间。修复后,将标本切成树脂-牙本质棒,并测试 μTBS、NL 和 DC。PCLD(%)、KHN、μTBS(MPa)、NL(%)和 DC(%)数据的数据分析采用方差分析和 Tukey 检验(α=0.05)。

结果

与其他组相比,320010 时观察到 KHN、μTBS 和 DC(p=0.00001)值显著降低,NL 和 PCLD(p=0.00001)值增加。与其他组相比,32005 时观察到更高的 KHN、μTBS 和 DC(p=0.000001)值。14005(7 J/cm2)和 140010(14 J/cm2)组表现出中间值(p=0.000001)。

结论

尽管在硬度、聚合物交联密度和纳米渗漏方面,3200 mW/cm2 时 5 秒组和 1400 mW/cm2 时 10 秒组的结果相似,但对于两种通用型胶粘剂对牙本质的粘结强度和转化率而言,使用更高的辐照度(3200 mW/cm2)仅 5 秒的效果更好。在更高的辐照度(3200 mW/cm2)下延长暴露时间(10 秒)的效果最差。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验