Uyar Osman Murat, Neubauer Jonas, Sadler Francoise, Konrad Eva-Maria, Gelisken Faik
Department of Ophthalmology, Ulus Liv Hospital, Istanbul 34340, Turkey.
Department of Ophthalmology, Eberhard-Karls University, Tuebingen 72076, Germany.
Int J Ophthalmol. 2022 Jul 18;15(7):1089-1094. doi: 10.18240/ijo.2022.07.08. eCollection 2022.
To evaluate the impact of the optical coherence tomography (OCT) scan patterns on the detection of the features associated with lamellar macular hole (LMH) and macular pseudohole (MPH).
This is a retrospective analysis of 100 consecutive eyes with LMH (=41) and MPH (=59) having at least three of the following OCT features, which include mandatory criteria for the diagnosis of LMH and MPH: Epiretinal membrane, epiretinal proliferation, verticalization, intraretinal cystoid spaces, foveoschisis, irregular foveal contour, foveal cavity with undermined edges, and ellipsoid line disruption. Primary outcome measurement was the detection frequency of the features in three different OCT scan patterns: 1) volume scan; 2) six radial scans (R6); and 3) vertical and horizontal radial scans (R2).
Of the total eight features, the maximal detection frequency was found as 4.45±1.45, 4.35±1.47, and 3.70±1.59, by the volume, R6 and R2, respectively. R2 was inferior to the other patterns in detection of the total features (<0.001), whereas R6 and volume patterns were found comparable (=0.312).
The physician should be aware that the selection of the OCT-scan pattern may influence the detection of mandatory morphological criteria for the diagnosis of LMH and MPH.
评估光学相干断层扫描(OCT)扫描模式对检测与板层黄斑裂孔(LMH)和黄斑假性裂孔(MPH)相关特征的影响。
这是一项对100只连续患眼的回顾性分析,其中LMH患眼41只,MPH患眼59只,这些患眼具有以下至少三种OCT特征,这些特征包括诊断LMH和MPH的必备标准:视网膜前膜、视网膜前增殖、垂直化、视网膜内囊样间隙、黄斑劈裂、不规则黄斑轮廓、边缘不完整的黄斑腔以及椭圆体线中断。主要观察指标是三种不同OCT扫描模式下各特征的检测频率:1)容积扫描;2)六径向扫描(R6);3)垂直和水平径向扫描(R2)。
在总共八项特征中,容积扫描、R6扫描和R2扫描检测到的最大频率分别为4.45±1.45、4.35±1.47和3.70±1.59。R2扫描在检测全部特征方面不如其他模式(<0.001),而R6扫描和容积扫描模式相当(=0.312)。
医生应意识到,OCT扫描模式的选择可能会影响对诊断LMH和MPH的必备形态学标准的检测。