Zorko M F
Ann Emerg Med. 1987 Jul;16(7):808-10. doi: 10.1016/s0196-0644(87)80582-6.
A case of a cornual ectopic pregnancy missed at attempted pregnancy termination and with subsequent rupture is presented. The positive pregnancy test at the time of presentation to the emergency department was mistakenly thought to be due to continued detectable blood levels of human chorionic gonadotrophin from the aborted pregnancy. This caused a delay in surgical intervention and subsequent rupture of the ectopic pregnancy with hypovolemic shock.
本文报告一例宫角异位妊娠病例,该病例在试图终止妊娠时被漏诊,随后发生破裂。患者到急诊科就诊时妊娠试验呈阳性,被错误地认为是由于流产后仍可检测到的人绒毛膜促性腺激素血水平所致。这导致手术干预延迟,随后异位妊娠破裂并引发低血容量性休克。