孕中期胎盘弹性成像预测子痫前期:一项前瞻性研究。

Placental elastography in second trimester preeclampsia prediction: A prospective study.

作者信息

Meena Rajkumar, Malik Amita, Jain Swarna, Batra Achla

机构信息

Department of Radiodiagnosis, Vardhman Mahavir Medical College and Safdarjung Hospital, New Delhi, India.

Department of Obstetrics and Gynaecology, Vardhman Mahavir Medical College and Safdarjung Hospital, New Delhi, India.

出版信息

Ultrasound. 2022 Aug;30(3):228-235. doi: 10.1177/1742271X211040543. Epub 2021 Sep 10.

Abstract

OBJECTIVE

The aim of the study was to evaluate the diagnostic potential of placental shear wave elastography in predicting preeclampsia at 16 to 20 weeks of gestation.

MATERIALS AND METHODS

A total of 230 pregnant women between 16 and 20 weeks of gestation were observed for the study. These women underwent shear wave elastography ElastPQ (Philips Healthcare, Bothell, Washington, USA) of the placenta. The mean value of placental shear modulus was obtained for each participant. These participants were followed up for the development of preeclampsia and were divided into two groups; group A included those who developed preeclampsia and group B included those who remained normotensive until delivery. The elasticity values of the two groups were compared, and the ROC curve was drawn to obtain the best cut-off value that would predict the onset of preeclampsia.

RESULTS

Placental shear modulus varied from 1.03 kPa to 7.4 kPa at 16 to 20 weeks of gestation with an average of 2.74 ± 0.87 kPa. There was a statistically significant difference in the mean value of elasticity between two groups, being 4.61 kPa in group A and 2.51 kPa in group B. Maximum diagnostic accuracy was obtained at 2.9667 kPa with area under the curve 0.970, sensitivity 92%, specificity 91.71%, positive predictive value 57.5% and negative predictive value 98.9%.

CONCLUSION

Stiffness of placenta, quantitatively measured by SWE at 16 to 20 weeks of gestation, is higher in the women who develop preeclampsia and hence may be used for predicting preeclampsia.

摘要

目的

本研究旨在评估胎盘剪切波弹性成像在预测妊娠16至20周子痫前期方面的诊断潜力。

材料与方法

本研究共观察了230例妊娠16至20周的孕妇。这些孕妇接受了胎盘的剪切波弹性成像ElastPQ(飞利浦医疗保健公司,美国华盛顿州博塞尔)检查。获取了每位参与者胎盘剪切模量的平均值。对这些参与者进行随访,观察子痫前期的发生情况,并将其分为两组;A组包括发生子痫前期的孕妇,B组包括直至分娩血压仍正常的孕妇。比较两组的弹性值,并绘制ROC曲线以获得预测子痫前期发病的最佳临界值。

结果

妊娠16至20周时,胎盘剪切模量在1.03kPa至7.4kPa之间变化,平均为2.74±0.87kPa。两组弹性平均值存在统计学显著差异,A组为4.61kPa,B组为2.51kPa。在2.9667kPa时获得最大诊断准确性,曲线下面积为0.970,敏感性为92%,特异性为91.71%,阳性预测值为57.5%,阴性预测值为98.9%。

结论

妊娠16至20周时通过剪切波弹性成像定量测量的胎盘硬度,在发生子痫前期的孕妇中较高,因此可用于预测子痫前期。

相似文献

本文引用的文献

3
Placental Elasticity as a New Non-invasive Predictive Marker of Pre-eclampsia.胎盘弹性作为子痫前期一种新的非侵入性预测标志物
Ultrasound Med Biol. 2019 Jan;45(1):93-97. doi: 10.1016/j.ultrasmedbio.2018.09.007. Epub 2018 Oct 17.