Kljajić M, Krajnik J
Clin Phys Physiol Meas. 1987 May;8(2):133-42. doi: 10.1088/0143-0815/8/2/004.
Ground reaction force is one of the most relevant parameters in the assessment of human gait. It is, however, difficult to measure without encumbering natural locomotion. A description of a system for measuring the vertical component of the ground reaction force and its distribution under the foot is given. The calibration procedure for the measuring shoes is described. The results of measurements are compared with those obtained from a force plate. Illustrative examples of the changes in pathological gait patterns of a hemiplegic patient during therapy by functional electrical stimulation are also given.
地面反作用力是评估人类步态时最相关的参数之一。然而,在不影响自然运动的情况下进行测量是很困难的。本文描述了一种用于测量地面反作用力垂直分量及其在足底分布的系统。阐述了测量鞋的校准程序。将测量结果与从测力板获得的结果进行了比较。还给出了偏瘫患者在功能性电刺激治疗期间病理步态模式变化的示例。