Suppr超能文献

大块充填复合树脂的比较评价:努氏显微硬度、径向拉伸强度和固化程度

Comparative Evaluation of Bulk-Fill Composite Resins: Knoop Microhardness, Diametral Tensile Strength and Degree of Conversion.

作者信息

Strini Bruna Scarcello, Marques Joyce Figueiredo de Lima, Pereira Renata, Sobral-Souza Danielle Ferreira, Pecorari Vanessa Gallego Arias, Liporoni Priscila Christiane Suzy, Aguiar Flávio Henrique Baggio

机构信息

Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil.

Dental School, Federal University of Mato Grosso do Sul, Campo Grande, MS, Brazil.

出版信息

Clin Cosmet Investig Dent. 2022 Aug 4;14:225-233. doi: 10.2147/CCIDE.S376195. eCollection 2022.

Abstract

PURPOSE

Bulk-fill composite resins were developed to reduce time and facilitate the restorative procedure. However, considering their recent introduction on the market and the new formulations, their performance still requires evaluation. This study aimed to evaluate Knoop microhardness (KHN), diametral tensile strength (DTS) and degree of conversion (DC) of three Bulk-Fill composite resins and a conventional one.

MATERIALS AND METHODS

Sixty samples (n = 15; 8 mm ø x 4 mm height) were confectioned using a mold. Filtek Bulk-Fill (FBF), Tetric N-Ceram Bulk-Fill (TNC) and SonicFill 2 (SF2) were placed in 4 mm increments, and Filtek Z350 (FZ350) was placed in 2 mm increments. The KHN of top and bottom surfaces were tested using Knoop Hardness tester at 10 gf/10s. The DTS was tested under compressive load at 1.0 mm/min. The DC was measured by Fourier Transform Infrared (FTIR) spectroscopy. Differences in DTS and DC were analyzed by ANOVA and Tukey post hoc test. For KHN, Kruskal-Wallis and Wilcoxon tests were performed at α = 0.05.

RESULTS

Top surfaces of all composite resins had higher KHN than bottom surfaces. At top and bottom surfaces, FZ350 showed higher KHN than TNC and SF2. The highest DTS was obtained by FBF, followed by FZ350 and SF2. The highest DC was obtained by SF2, the lowest one was obtained by FBF.

CONCLUSION

From Bulk-Fill composite resins, FBF presented the best KHN and DTS results. The SF2 showed the best DC. Further studies are required to ensure whether these differences can negatively influence the behavior of in vivo restorations.

摘要

目的

大容量充填复合树脂的研发旨在减少时间并简化修复过程。然而,鉴于它们最近才进入市场且有新的配方,其性能仍需评估。本研究旨在评估三种大容量充填复合树脂和一种传统复合树脂的努氏显微硬度(KHN)、径向拉伸强度(DTS)和转化率(DC)。

材料与方法

使用模具制作60个样本(n = 15;直径8 mm×高4 mm)。Filtek Bulk-Fill(FBF)、Tetric N-Ceram Bulk-Fill(TNC)和SonicFill 2(SF2)以4 mm的增量放置,Filtek Z350(FZ350)以2 mm的增量放置。使用努氏硬度测试仪在10 gf/10s的条件下测试顶面和底面的KHN。在1.0 mm/min的压缩载荷下测试DTS。通过傅里叶变换红外(FTIR)光谱法测量DC。通过方差分析和Tukey事后检验分析DTS和DC的差异。对于KHN,在α = 0.05的水平下进行Kruskal-Wallis和Wilcoxon检验。

结果

所有复合树脂的顶面KHN均高于底面。在顶面和底面,FZ350的KHN高于TNC和SF2。FBF获得最高的DTS,其次是FZ350和SF2。SF2获得最高的DC,FBF获得最低的DC。

结论

在大容量充填复合树脂中,FBF呈现出最佳的KHN和DTS结果。SF2显示出最佳的DC。需要进一步研究以确定这些差异是否会对体内修复的行为产生负面影响。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/db33/9359371/f472042bd73d/CCIDE-14-225-g0001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验