High-performance liquid chromatography was evaluated as a rapid means of identifying obligately anaerobic gram-positive cocci of medical interest. Isolates were inoculated into a defined chemical medium consisting primarily of amino acids and were incubated aerobically for 1 h at 35 degrees C. After removal of organisms, the supernatant fluids were derivatized for 1 min at room temperature by the addition of o-phthalaldehyde. The total time required to run a chromatogram was approximately 50 min. Standardized peak heights for each medium component and any new peaks formed were calculated for each isolate and compared with those for uninoculated control medium. Multiple isolates of various species of anaerobic gram-positive cocci gave consistent patterns of medium utilization that could be used for identification purposes. This method can easily be adapted for laboratory use and has the potential for automated microbial identification.
高效液相色谱法被评估为一种快速鉴定具有医学意义的专性厌氧革兰氏阳性球菌的方法。将分离株接种到主要由氨基酸组成的特定化学培养基中,并在35℃有氧条件下孵育1小时。去除菌体后,通过添加邻苯二甲醛使上清液在室温下衍生化1分钟。运行色谱图所需的总时间约为50分钟。计算每个分离株每种培养基成分的标准化峰高以及形成的任何新峰,并与未接种对照培养基的峰高进行比较。多种厌氧革兰氏阳性球菌的多个分离株给出了一致的培养基利用模式,可用于鉴定目的。该方法可轻松适用于实验室使用,具有自动微生物鉴定的潜力。