Suppr超能文献

评估氟化物对镍钛和铜镍钛正畸弓丝机械性能的影响:一项研究。

Assessment of Impact of Fluoride on Mechanical Properties of NiTi and CuNiTi Orthodontic Archwires: An Study.

机构信息

Department of Orthodontics, Dr BR Ambedkar Institute of Dental Sciences and Hospital, Patna, Bihar, India.

Department of Orthodontics, Yerala Dental College Navi Mumbai, Maharashtra, India.

出版信息

J Contemp Dent Pract. 2022 May 1;23(5):548-551.

Abstract

AIM

The current study was carried out to assess the impact on the mechanical properties of orthodontic wires such as the nickel-titanium (NiTi) and copper-nickel-titanium (CuNiTi) wires by fluoride available in various prophylactic products.

MATERIALS AND METHODS

Fifty-six wire specimens were randomly divided into two groups-control group in which deionized water was used as a medium and study group in which Phos-Flur gel was used. Both study group and control group were divided into two subgroups-NiTi wire group: 0.019 × 0.025 inch NiTi archwires (14 specimens) and CuNiTi wire group: 0.019 × 0.025 inch CuNiTi archwires (14 specimens). Testing of all the wires was done under a universal force testing machine.

RESULTS

Mean loading force among NiTi wire group and CuNiTi wire group specimens with deionized water as a medium was 682.6 and 397.4 MPa, respectively, while the mean loading force among NiTi wire group and CuNiTi wire group specimens with Phos-Flur gel as a medium was 596.1 and 368.4 MPa, respectively. While comparing between study group and control group among NiTi wires, significant results were obtained. Also, while comparing between study group and control group among CuNiTi wires, significant results were obtained.

CONCLUSION

Following exposure to fluoride agents, NiTi wires and CuNiTi wires are significantly associated with reduced mechanical properties.

CLINICAL SIGNIFICANCE

Although fluoride acts as a vital adjunct in maintaining oral hygiene, particularly among patients undergoing fixed orthodontic treatment, its influence on the mechanical properties of the wires is an area to be explored further; thereby, its use is to be monitored.

摘要

目的

本研究旨在评估各种预防性产品中含有的氟化物对正畸丝(如镍钛(NiTi)和铜镍钛(CuNiTi)丝)机械性能的影响。

材料和方法

将 56 个丝样本随机分为两组-对照组,其中使用去离子水作为介质;研究组,其中使用 Phos-Flur 凝胶。研究组和对照组均分为两组-NiTi 丝组:0.019×0.025 英寸 NiTi 弓丝(14 个样本)和 CuNiTi 丝组:0.019×0.025 英寸 CuNiTi 弓丝(14 个样本)。所有丝的测试均在万能力试验机下进行。

结果

以去离子水为介质的 NiTi 丝组和 CuNiTi 丝组样本的平均加载力分别为 682.6 和 397.4 MPa,而以 Phos-Flur 凝胶为介质的 NiTi 丝组和 CuNiTi 丝组样本的平均加载力分别为 596.1 和 368.4 MPa。在 NiTi 丝中比较研究组和对照组时,得到了显著结果。同样,在 CuNiTi 丝中比较研究组和对照组时,也得到了显著结果。

结论

暴露于氟化物后,NiTi 丝和 CuNiTi 丝的机械性能显著降低。

临床意义

尽管氟化物作为维持口腔卫生的重要辅助手段,特别是在接受固定正畸治疗的患者中,但它对丝的机械性能的影响是一个有待进一步探索的领域;因此,需要对其使用进行监测。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验