Acta Orthop Belg. 2022 Jun;88(2):410-417. doi: 10.52628/88.2.9037.
The aim of this study is to report the early results of the MatOrtho arthroplasty, a newer generation resurfacing implant of the proximal interphalangeal joint. We performed a prospective cohort review of all MatOrtho arthroplasties implanted between 12/2013 and 05/2018 by a single surgeon at a single institution because of primary osteoarthritis, with a minimum follow-up of two years. Patient demographics, diagnosis, implant revision and other surgical interventions were recorded. Subjective and objective outcomes were evaluated, including range of motion, Patient Reported Outcome Measures and radiographic assessment. A total of 34 implants were inserted in 25 patients. Two implants were lost to follow-up. Pain scores improved significantly (mean VAS pre- op 7, mean VAS post-op 1, p < 0.05). Active range of motion improved in 83% (25/30) of joints, with a mean improvement of the total arc of motion of 25 degrees. On radiographic assessment, no signs of circumferential lucency or subsidence were observed. Additional surgery was necessary for three out of 32 implants, including implant removal in two cases. 93.75% (30/32) implants survived after a mean follow-up of 33 months. Our results confirm that at least at short term follow up, the MatOrtho PIP arthroplasty can be a successful procedure with high patient satisfaction and functional improvement.
本研究旨在报告新一代指间关节表面置换假体 MatOrtho 的早期结果。我们对一名外科医生在一家机构于 2013 年 12 月至 2018 年 5 月期间因原发性骨关节炎而植入的所有 MatOrtho 关节置换假体进行了前瞻性队列研究,随访时间至少为两年。记录了患者的人口统计学、诊断、植入物翻修和其他手术干预情况。评估了主观和客观的结果,包括活动范围、患者报告的结果测量和影像学评估。共植入 34 个假体,涉及 25 名患者。有 2 个假体失访。疼痛评分显著改善(术前 VAS 平均 7,术后 VAS 平均 1,p<0.05)。83%(25/30)的关节主动活动度改善,总活动度平均改善 25 度。在影像学评估中,未观察到环状透光或下沉的迹象。32 个假体中有 3 个(2 个病例为假体取出)需要进一步手术。平均随访 33 个月后,有 93.75%(30/32)的假体存活。我们的结果证实,至少在短期随访中,MatOrtho PIP 关节置换术是一种成功率高、患者满意度和功能改善高的成功手术。