Suppr超能文献

使用动态对比CT测量进食状态下血管系统中间接辐射诱导的灌注变化。

Measuring Indirect Radiation-Induced Perfusion Change in Fed Vasculature Using Dynamic Contrast CT.

作者信息

Wuschner Antonia E, Flakus Mattison J, Wallat Eric M, Reinhardt Joseph M, Shanmuganayagam Dhanansayan, Christensen Gary E, Bayouth John E

机构信息

University of Wisconsin, Madison, WI 53706, USA.

University of Iowa, Iowa City, IA 52242, USA.

出版信息

J Pers Med. 2022 Jul 30;12(8):1254. doi: 10.3390/jpm12081254.

Abstract

Recent functional lung imaging studies have presented evidence of an “indirect effect” on perfusion damage, where regions that are unirradiated or lowly irradiated but that are supplied by highly irradiated regions observe perfusion damage post-radiation therapy (RT). The purpose of this work was to investigate this effect using a contrast-enhanced dynamic CT protocol to measure perfusion change in five novel swine subjects. A cohort of five Wisconsin Miniature Swine (WMS) were given a research course of 60 Gy in five fractions delivered locally to a vessel in the lung using an Accuray Radixact tomotherapy system with Synchrony motion tracking to increase delivery accuracy. Imaging was performed prior to delivering RT and 3 months post-RT to yield a 28−36 frame image series showing contrast flowing in and out of the vasculature. Using MIM software, contours were placed in six vessels on each animal to yield a contrast flow curve for each vessel. The contours were placed as follows: one at the point of max dose, one low-irradiated (5−20 Gy) branching from the max dose vessel, one low-irradiated (5−20 Gy) not branching from the max dose vessel, one unirradiated (<5 Gy) branching from the max dose vessel, one unirradiated (<5 Gy) not branching from the max dose vessel, and one in the contralateral lung. Seven measurements (baseline-to-baseline time and difference, slope up and down, max rise and value, and area under the curve) were acquired for each vessel’s contrast flow curve in each subject. Paired Student t-tests showed statistically significant (p < 0.05) reductions in the area under the curve in the max dose, and both fed contours indicating an overall reduction in contrast in these regions. Additionally, there were statistically significant reductions observed when comparing pre- and post-RT in slope up and down in the max dose, low-dose fed, and no-dose fed contours but not the low-dose not-fed, no-dose not-fed, or contralateral contours. These findings suggest an indirect damage effect where irradiation of the vasculature causes a reduction in perfusion in irradiated regions as well as regions fed by the irradiated vasculature.

摘要

近期的肺部功能成像研究已经提供了关于灌注损伤“间接效应”的证据,即在未受照射或低剂量照射但由高剂量照射区域供血的区域,在放射治疗(RT)后观察到灌注损伤。这项工作的目的是使用对比增强动态CT方案来研究这种效应,以测量五只新的猪受试者的灌注变化。一组五只威斯康星小型猪(WMS)接受了一个研究疗程,使用带有同步运动跟踪的Accuray Radixact断层放射治疗系统,将60 Gy分五次局部照射到肺部的一条血管。在进行放射治疗之前和放疗后3个月进行成像,以生成一个28 - 36帧的图像序列,显示造影剂流入和流出血管系统。使用MIM软件,在每只动物的六条血管上放置轮廓,以生成每条血管的造影剂流动曲线。轮廓放置如下:一个在最大剂量点,一个从最大剂量血管分支的低剂量照射(5 - 20 Gy)区域,一个不从最大剂量血管分支的低剂量照射(5 - 20 Gy)区域,一个从最大剂量血管分支的未受照射(<5 Gy)区域,一个不从最大剂量血管分支的未受照射(<5 Gy)区域,以及一个在对侧肺中。对每个受试者每条血管的造影剂流动曲线进行七项测量(基线到基线时间和差值、上升和下降斜率、最大上升和值以及曲线下面积)。配对学生t检验显示,最大剂量区域以及两个供血轮廓区域的曲线下面积有统计学显著(p < 0.05)减少,表明这些区域的造影剂总体减少。此外,在比较放疗前后时,最大剂量、低剂量供血和无剂量供血轮廓的上升和下降斜率有统计学显著减少,但低剂量未供血、无剂量未供血或对侧轮廓则没有。这些发现表明存在一种间接损伤效应,即血管照射会导致照射区域以及由受照射血管供血区域的灌注减少。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/a79b/9410208/107cbab2ee51/jpm-12-01254-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验