Abstract

INTRODUCTION

Animal carcasses differ in composition from other types of solid waste, and through prior testing it was determined that cycle parameters applied to general, solid biohazardous waste did not ensure proper sterilization of ferret carcasses.

OBJECTIVES

The goals of this study were to develop and validate an autoclave cycle that would ensure the decontamination of infectious animal carcasses before removal from an animal biosafety level 2/3 containment suite for downstream disposal and to test different ways to prepare and package animal carcasses for autoclaving.

METHODS

Intact ferret carcasses were implanted with biological indicators, and the carcasses were placed in biohazard bags, then into metal pans. To test the efficacy of the autoclave cycle on larger biomasses, 1, 2, or 4 ferret carcasses were placed in a biohazard bag. A total of 4 carcasses were placed in each pan. An autoclave cycle was created to begin the study. After initial tests, minor modifications to the initial test cycle parameters were made, and a new cycle was validated for ferret carcasses up to 2 kg each. Parameters for the validated cycle were as follows: sterilization time 240 minutes, temperature 125°C, 5 prevacuum pulses, and chamber pressure 15 psi.

RESULTS

The results of this study indicate that an extended sterilization time is required to successfully decontaminate animal carcasses compared with regular, solid, and biohazardous waste.

CONCLUSIONS

This study demonstrates that it is possible to sterilize multiple intact ferret carcasses per load under validated autoclave cycle conditions.

摘要

引言

动物尸体的成分与其他类型的固体废物不同,通过先前的测试发现,应用于一般固体生物危害废物的循环参数不能确保对雪貂尸体进行适当的消毒。

目的

本研究的目标是开发并验证一种高压灭菌循环,以确保在将感染性动物尸体从动物生物安全2/3级隔离设施中取出进行下游处理之前对其进行去污,并测试为高压灭菌准备和包装动物尸体的不同方法。

方法

将完整的雪貂尸体植入生物指示剂,然后将尸体放入生物危害袋中,再放入金属盘中。为了测试高压灭菌循环对更大生物量的效果,将1、2或4只雪貂尸体放入一个生物危害袋中。每个盘中总共放置4具尸体。创建了一个高压灭菌循环来开始研究。在初步测试后,对初始测试循环参数进行了微小修改,并验证了一个新的循环,适用于每只重达2千克的雪貂尸体。验证循环的参数如下:灭菌时间240分钟,温度125°C,5次预真空脉冲,腔室压力15磅/平方英寸。

结果

本研究结果表明,与常规的固体生物危害废物相比,需要延长灭菌时间才能成功对动物尸体进行去污。

结论

本研究表明,在经过验证的高压灭菌循环条件下,每次装载可以对多具完整的雪貂尸体进行消毒。

相似文献

4
Validation of an Autoclave Procedure for Sterilization of Mouse () Carcasses.小鼠尸体高压灭菌程序的验证
J Am Assoc Lab Anim Sci. 2019 Jan 1;58(1):87-91. doi: 10.30802/AALAS-JAALAS-18-000020. Epub 2018 Nov 6.
7
Measurement of Equilibration Time of Dry Goods Loads in Autoclaves.高压灭菌器中干货负载平衡时间的测量。
PDA J Pharm Sci Technol. 2019 Jul-Aug;73(4):293-319. doi: 10.5731/pdajpst.2018.009225. Epub 2019 Feb 15.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验