Abstract

Although research on the ionised fraction of serum calcium (Ca++) started some 50 years ago, normal values and, above all, the methods of determination are still controversial. The use of calcium ion selective electrodes greatly enhanced and improved the measurement of Ca++. A study was carried out to: evaluate two Ca++ analysers (Radiometer ICA1 (Copenhagen, Denmark) and Orion SS-20 (Orion Biomedical, Cambridge, Mass., USA) ); correlate serum ionised calcium, total calcium and albumin levels in various normal and pathological states; and determine the values of Ca++ in healthy black subjects. The two analysers gave results showing very good correlation over a wide range (r = 0.986). Results for ionised Ca++ v. total calcium (TCa) showed a significant linear correlation (r = 0.956). Correcting TCa for variations in serum albumin concentrations did not improve this correlation (r = 0.9114). Reference normal values for Ca++ were established for healthy blacks, cord blood values being highest (mean 1.356 +/- 0.139 mmol/l) and adult values lowest (mean 1.159 +/- 0.04 mmol/l). Although the results obtained on the analysers were similar, the Radiometer ICA1 requires less blood and measures pH simultaneously. Correcting TCa for the variation in albumin within the normal range seemed to be of little value in assessing Ca++. The determination of TCa in most clinical situations is a good reflection of Ca++.

摘要

尽管对血清钙离子(Ca++)的研究大约在50年前就已开始,但正常数值,尤其是测定方法仍存在争议。钙离子选择性电极的使用极大地增强和改进了Ca++的测量。开展了一项研究,目的是:评估两种Ca++分析仪(Radiometer ICA1(丹麦哥本哈根)和Orion SS - 20(美国马萨诸塞州剑桥市的Orion Biomedical公司));关联各种正常和病理状态下的血清离子钙、总钙和白蛋白水平;以及确定健康黑人的Ca++值。这两种分析仪的结果在很宽的范围内显示出非常好的相关性(r = 0.986)。离子钙(Ca++)与总钙(TCa)的结果显示出显著的线性相关性(r = 0.956)。针对血清白蛋白浓度的变化校正总钙并没有改善这种相关性(r = 0.9114)。为健康黑人建立了Ca++的参考正常值,脐血值最高(均值1.356 +/- 0.139 mmol/l),成人值最低(均值1.159 +/- 0.04 mmol/l)。尽管在分析仪上获得的结果相似,但Radiometer ICA1所需血量更少且能同时测量pH值。在正常范围内针对白蛋白的变化校正总钙在评估Ca++方面似乎价值不大。在大多数临床情况下测定总钙能很好地反映Ca++。

相似文献

2
Protein interferes with ionised calcium measurement at the reference electrode liquid junction.
Ann Clin Biochem. 1987 Jul;24 ( Pt 4):400-7. doi: 10.1177/000456328702400409.
4
Determination of ionised calcium by ion selective electrode is not independent of albumin concentration.
Clin Chim Acta. 1986 Jul 30;158(2):129-37. doi: 10.1016/0009-8981(86)90228-7.
5
Anomalies in pH 7.40 correction in ionised calcium analysers.离子钙分析仪中pH 7.40校正的异常情况。
Ann Clin Biochem. 1989 Nov;26 ( Pt 6):542-6. doi: 10.1177/000456328902600615.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验