Polyethylene terephthalate clamps: Optimization in endodontic and restorative practices.

作者信息

Ferreira E Cunha Anna-Flávia, Madalena Isabela-Ribeiro, Küchler Erika-Calvano, Pereira Tiago-Lima, Honorato Richard, de Menezes Fernando-Carlos-Hueb, Lepri César-Penazzo, Oliveira Maria-Angélica-Hueb-de Menezes

机构信息

Department of Biomaterials, University of Uberaba - UNIUBE, Uberaba, Minas Gerais, Brazil.

Department of Dentistry, University of Joinville Region, Joinville, Santa Catarina, Brazil.

出版信息

J Clin Exp Dent. 2022 Aug 1;14(8):e621-e624. doi: 10.4317/jced.59603. eCollection 2022 Aug.

Abstract

BACKGROUND

There is a growing search for innovations in dental materials and instruments and, therefore, an increase need to optimize the instruments used in the absolute isolation. The gold standard procedure contributes significantly to the quality of restorative and endodontic procedures. Thus, the aim of the present study was to evaluate the radiopacity of polyethylene terephthalate polymer clamps and compare them to conventional metal clamps.

MATERIAL AND METHODS

The polyethylene terephthalate clamp was developed at the University of Uberaba (Patent application #PI0901719-4, Uberaba, MG, Brazil). Five polyethylene terephthalate clamps and five conventional metal clamps were used. The clamps were positioned, next to an aluminum scale, under the same phosphor plate to perform 3 radiographs. The locator cylinder was set perpendicular to the radiographic films at a focal length of 20 cm and set to 60 kVp and 0.06 seconds. After image processing, optical density values were read using DBWin 5.0.4 software. The mean of the 3 readings taken on each clamp was adopted as the radiodensity of the specimen. The differences between the groups were compared using Student's t-test (<0.05).

RESULTS

Polyethylene terephthalate clamps demonstrated significantly lower radiopacity than conventional metal clamps (<0.05).

CONCLUSIONS

Polyethylene terephthalate clamps have lower radiopacity when compared to conventional metal clamps. Rubber Dams, Dentistry, Operative, Endodontics.

摘要

背景

对牙科材料和器械创新的探索日益增加,因此,优化用于绝对隔离的器械的需求也在增加。金标准程序对修复和牙髓治疗程序的质量有显著贡献。因此,本研究的目的是评估聚对苯二甲酸乙二醇酯聚合物夹的射线不透性,并将其与传统金属夹进行比较。

材料与方法

聚对苯二甲酸乙二醇酯夹由乌贝拉巴大学研发(专利申请号#PI0901719-4,巴西米纳斯吉拉斯州乌贝拉巴)。使用了五个聚对苯二甲酸乙二醇酯夹和五个传统金属夹。将夹子与铝标尺一起放置在同一磷光板下,进行3次射线照相。定位筒垂直于射线胶片设置,焦距为20 cm,设置为60 kVp和0.06秒。图像处理后,使用DBWin 5.0.4软件读取光密度值。每个夹子上读取的3次读数的平均值作为样本的射线密度。使用学生t检验比较组间差异(<0.05)。

结果

聚对苯二甲酸乙二醇酯夹的射线不透性明显低于传统金属夹(<0.05)。

结论

与传统金属夹相比,聚对苯二甲酸乙二醇酯夹的射线不透性较低。橡胶障、牙科、手术、牙髓病学。