Suppr超能文献

评估数字化口内直接印模技术在单侧唇腭裂 2 例婴儿中的准确性与数字化传统印模比较。

Evaluating the accuracy of intraoral direct digital impressions in 2 infants with unilateral cleft lip and palate compared with digitized conventional impression.

机构信息

Department of Orthodontics, School of Denistry, University of Detroit Mercy, Detroit, Mich.

ITX PROS, Lewes, Del.

出版信息

Am J Orthod Dentofacial Orthop. 2022 Sep;162(3):403-409. doi: 10.1016/j.ajodo.2021.09.015.

Abstract

INTRODUCTION

Presurgical infant orthopedics was introduced as an interceptive approach for treating cleft lip and/or palate (CLP). This study aimed to evaluate the intraoral digital impression technique as a viable alternative to conventional impression in infants with unilateral CLP.

METHODS

Trios 3-Shape scanner (3Shape, Copenhagen, Denmark) was used for intraoral scanning of the infants' maxillary arches to provide a direct digital scan (DDS). In addition, conventional impressions of the same patients were taken in a hospital setting, and the resultant stone models were digitized using the same scanner to create an indirect digital scan (IDS). Both scans (DDS and IDS) were exported in stereolithography format, and the resultant stereolithography files were imported into computer-assisted-design software (Exocad DentalCAD; exocad GmbH, Darmstadt, Germany) for 3-dimensional surface model superimposition. Differences between the 2 surfaces were quantified in millimeters and visually displayed by a color map.

RESULTS

Three-dimensional surface model superimposition of the DDS and IDS scans showed an excellent agreement between both approaches, in which differences ranged from 0.01 mm to 0.1 mm CONCLUSIONS: Intraoral direct digital impression in infants with unilateral CLP is a safe, accurate, and time-efficient technique, which can be a viable alternative to conventional impression. This will aid in overcoming the challenges and complications that are frequently associated with using conventional impressions in infants with unilateral CLP, thus reducing the burden of care not only on the patients' families but also on the care providers.

摘要

简介

术前婴儿矫形术作为一种治疗唇腭裂(CLP)的干预方法被引入。本研究旨在评估口腔内数字印模技术作为单侧 CLP 婴儿传统印模的可行替代方法。

方法

使用 3Shape 扫描仪(3Shape,哥本哈根,丹麦)对婴儿上颌弓进行口腔内扫描,提供直接数字扫描(DDS)。此外,在医院环境中对同一患者进行传统印模,并使用相同的扫描仪对所得石模型进行数字化,以创建间接数字扫描(IDS)。将两次扫描(DDS 和 IDS)均以立体光刻格式导出,并将所得立体光刻文件导入计算机辅助设计软件(Exocad DentalCAD;Exocad GmbH,达姆施塔特,德国)以进行三维表面模型叠加。以毫米为单位量化两次扫描之间的差异,并通过彩色地图直观显示。

结果

DDS 和 IDS 扫描的三维表面模型叠加显示两种方法之间具有极好的一致性,差异范围在 0.01 毫米至 0.1 毫米之间。

结论

单侧 CLP 婴儿的口腔内直接数字印模是一种安全、准确且高效的技术,可作为传统印模的可行替代方法。这将有助于克服在单侧 CLP 婴儿中使用传统印模时经常出现的挑战和并发症,从而不仅减轻患者家庭的护理负担,也减轻护理提供者的负担。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验