Tıskaoğlu Nesime Setge, Yazıcı Alper
Ophthalmology Department, Dr. Ersin Arslan's Research and Education Hospital, Gaziantep, Turkey.
Ophthalmology Department, İzmir Torbalı State Hospital, İzmir, Turkey.
Int Ophthalmol. 2023 Mar;43(3):965-971. doi: 10.1007/s10792-022-02498-w. Epub 2022 Sep 2.
To measure tear osmolarity, Schirmer I test and tear break-up time (TBUT) values in the obstructed and non-obstructed fellow eye of unilateral primary acquired nasolacrimal duct obstruction (PANDO) patients and compare them with healthy controls.
In this prospective noninterventional study, the tear osmolarity, Schirmer I test, and TBUT values from unilateral PANDO eyes, fellow eyes, and control eyes of all subjects were measured.
The study included 114 eyes of 30 PANDO patients as well as 27 healthy controls. There was a significant difference between TBUT and Schirmer values of fellow eyes and PANDO eyes (p = 0,035; p = 0,001). There was no significant difference in any of the ocular surface parameters between PANDO eyes and control eyes (p > 0.05). When fellow eyes were compared to control eyes, there was a significant difference in TBUT (p = 0.046).
Decreased TBUT was exhibited by the fellow eye of unilateral PANDO patients, compared to the PANDO side and controls. Compensatory changes in PANDO eyes due to a decrease in the tear secretion reflex may lead to tear dysfunction of the fellow eye. Clinicians should assess tear stability in the fellow eye of PANDO patients as this could be leading to added symptomatic complaints.
测量单侧原发性获得性鼻泪管阻塞(PANDO)患者患侧眼及健侧眼的泪液渗透压、Schirmer I试验和泪膜破裂时间(TBUT)值,并与健康对照者进行比较。
在这项前瞻性非干预性研究中,测量了所有受试者的单侧PANDO患侧眼、健侧眼和对照眼的泪液渗透压、Schirmer I试验和TBUT值。
该研究纳入了30例PANDO患者的114只眼以及27名健康对照者。健侧眼与PANDO患侧眼的TBUT和Schirmer值之间存在显著差异(p = 0.035;p = 0.001)。PANDO患侧眼与对照眼的任何眼表参数均无显著差异(p > 0.05)。当健侧眼与对照眼进行比较时,TBUT存在显著差异(p = 0.046)。
与PANDO患侧眼和对照眼相比,单侧PANDO患者的健侧眼TBUT降低。由于泪液分泌反射减少,PANDO患侧眼的代偿性变化可能导致健侧眼泪液功能障碍。临床医生应评估PANDO患者健侧眼的泪液稳定性,因为这可能会导致更多的症状性主诉。