Suppr超能文献

一种使用常规非接触式额温计测量舌下温度的新方法。

A novel method for measuring sublingual temperature using conventional non-contact forehead thermometer.

机构信息

Department of Internal Medicine, Kasturba Medical College,Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka, 575001, India.

Department of Pharmacology, Nanjappa Hospitals, Durgigudi, Shivamogga, Karnataka, 577201, India.

出版信息

F1000Res. 2022 Jan 7;11:13. doi: 10.12688/f1000research.74876.3. eCollection 2022.

Abstract

Sublingual temperature measurement is a quick and accurate representation of oral temperature and corresponds closely with core temperature. Sub-lingual temperature measurement using non-contact infrared thermometers has not been studied for this purpose and if accurate they would be a reliable and convenient way of recording temperature of a patient very quickly. The aim of the study was to evaluate the utility of recording sublingual temperature using an infrared non-contact thermometer and establish its accuracy by comparing the readings with tympanic thermometer recordings. This cross-sectional study was carried out in 29 patients (328 paired recordings from sublingual and tympanic sites simultaneously). Subjects were requested to keep their mouth closed for five minutes before recording the temperature. Sublingual recordings were performed for each patient at different times of the day using an infrared thermometer. The infrared thermometer was quickly brought 1cm away from the sublingual part of the tongue and the recordings were then done immediately. Readings were compared with the corresponding tympanic temperature. The non-contact sublingual temperature correlated very closely with tympanic temperature (r=0.86, p<0.001). The mean difference between the infrared sublingual and tympanic temperature was 0.21°C (standard deviation [SD]:0.48°C, 95% confidence interval [CI] of 0.16-0.27). The intra-class correlation co-efficient (ICC) between core and sublingual temperatures was 0.830 (95% CI: 0.794 to 0.861) p<0.001. The sensitivity of sublingual IR (infrared) temperature of 37.65°C was 90% and specificity was 89% for core temperature >38°C. This innovative modification of using the forehead infrared thermometer to measure the sublingual temperature offers an accurate, rapid and non-contact estimation of core temperature.

摘要

舌下温度测量是口腔温度的快速准确表示,与核心温度密切相关。尚未对此目的进行使用非接触式红外体温计进行舌下温度测量的研究,如果准确的话,它们将是一种快速可靠的记录患者体温的便捷方式。本研究的目的是评估使用非接触式红外体温计记录舌下温度的效用,并通过与鼓膜温度计的记录比较来确定其准确性。这项横断面研究共纳入了 29 名患者(舌下和鼓膜同时记录 328 对记录)。要求患者在记录体温前将口腔闭合五分钟。使用红外体温计为每位患者在一天中的不同时间进行舌下温度记录。红外体温计快速移至舌下 1cm 处,然后立即进行记录。将读数与相应的鼓膜温度进行比较。非接触式舌下温度与鼓膜温度相关性非常好(r=0.86,p<0.001)。红外舌下温度与鼓膜温度之间的平均差值为 0.21°C(标准差 [SD]:0.48°C,95%置信区间 [CI]:0.16-0.27)。核心温度和舌下温度之间的组内相关系数(ICC)为 0.830(95% CI:0.794-0.861),p<0.001。舌下 IR(红外)温度为 37.65°C 的敏感性为 90%,核心温度>38°C 的特异性为 89%。这种创新的使用额部红外体温计测量舌下温度的方法可提供准确、快速且非接触式的核心温度估计。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/9948/9418756/51112c61960e/f1000research-11-137878-g0000.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验