Suppr超能文献

家庭与诊室漂白对不同CAD/CAM陶瓷材料显微硬度和颜色的影响

The Effect of Home and In-Office Bleaching on Microhardness and Color of Different CAD/CAM Ceramic Materials.

作者信息

Alshali Ruwaida Z, Alqahtani Mohammed A

机构信息

Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, King Abdulaziz University, Jeddah 21589, Saudi Arabia.

Prosthetic Dental Science, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia.

出版信息

Materials (Basel). 2022 Aug 28;15(17):5948. doi: 10.3390/ma15175948.

Abstract

The aim of this study is to assess the effect of different bleaching agents on microhardness and color of CAD/CAM ceramics including IPS e.max CAD (lithium disilicate), VITA ENAMIC (polymer-infiltrated ceramic), and Celtra Duo CAD (zirconia-reinforced lithium silicate). Materials' samples were divided into three groups (n = 10) and each received a different bleaching treatment; 20% carbamide peroxide, 35% carbamide peroxide, and 40% hydrogen peroxide. A fourth group was stored in water acting as a control. Vickers microhardness and spectrophotometric color measurements were taken at baseline and after bleaching. IPS e.max CAD showed a significant reduction (about 14%), while VITA ENAMIC showed a significant increase (about 78%) in microhardness after bleaching ( ˂ 0.001). Celtra Duo CAD did not demonstrate a significant change in microhardness ( ≥ 0.609). The color difference (ΔE) after bleaching was 0.29 (±0.08), 2.84 (±0.64), and 1.99 (±0.37) for IPS e.max CAD, VITA ENAMIC, and Celtra Duo CAD, respectively. It could be concluded that the effect of bleaching on color and microhardness was mainly material-dependent. Bleaching significantly affected the microhardness of IPS e.max CAD and VITA ENAMIC. The color difference was within the clinically imperceptible range for IPS e.max CAD, while VITA ENAMIC and Celtra Duo CAD demonstrated perceptible color change.

摘要

本研究的目的是评估不同漂白剂对CAD/CAM陶瓷(包括义获嘉e.max CAD(二硅酸锂)、威兰德全瓷(聚合物渗透陶瓷)和Celtra Duo CAD(氧化锆增强二硅酸锂))显微硬度和颜色的影响。将材料样本分为三组(n = 10),每组接受不同的漂白处理;20%过氧化脲、35%过氧化脲和40%过氧化氢。第四组保存在水中作为对照。在漂白前后分别进行维氏显微硬度和分光光度颜色测量。漂白后,义获嘉e.max CAD的显微硬度显著降低(约14%),而威兰德全瓷的显微硬度显著增加(约78%)(P ˂ 0.001)。Celtra Duo CAD的显微硬度未显示出显著变化(P≥0.609)。义获嘉e.max CAD、威兰德全瓷和Celtra Duo CAD漂白后的颜色差异(ΔE)分别为0.29(±0.08)、2.84(±0.64)和1.99(±0.37)。可以得出结论,漂白对颜色和显微硬度的影响主要取决于材料。漂白对义获嘉e.max CAD和威兰德全瓷的显微硬度有显著影响。义获嘉e.max CAD的颜色差异在临床不可察觉范围内,而威兰德全瓷和Celtra Duo CAD则显示出可察觉的颜色变化。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4c42/9457352/67577e07837c/materials-15-05948-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验