Suppr超能文献

血浆中拉贝洛尔液相色谱测定法的改进

Improved liquid-chromatographic assay of labetalol in plasma.

作者信息

Luke D R, Matzke G R, Clarkson J T, Awni W M

出版信息

Clin Chem. 1987 Aug;33(8):1450-2.

PMID:3608164
Abstract

This is an assay for labetalol in plasma by "high-performance" liquid chromatography, with 5-(2-[4-(4-chlorophenyl)ethyl]) salicylamide hemihydrate as the internal standard. Plasma samples (500 microL) are extracted with acetonitrile, evaporated under nitrogen, reconstituted in the mobile phase, and injected onto a PRP-1 (Hamilton) column packed with particles of poly(styrene-divinylbenzene) copolymer. Fluorescence, enhanced by post-column introduction of NH4OH, was measured in the effluent (excitation wavelength 340 nm, emission wavelength 418 nm). Retention times for labetalol and the internal standard were 1.99 and 3.32 min, respectively. Inter- and intraday CVs for high and low concentrations of the drug were less than 7.5%. The assay standard curve is linear from 1 to 250 micrograms/L. Some commonly co-administered drugs were tested and did not interfere.

摘要

这是一种采用“高效”液相色谱法测定血浆中拉贝洛尔的方法,以5-(2-[4-(4-氯苯基)乙基])水杨酰胺半水合物作为内标。血浆样本(500微升)用乙腈萃取,氮气吹干,用流动相复溶,然后注入填充有聚(苯乙烯-二乙烯基苯)共聚物颗粒的PRP-1(汉密尔顿)柱。通过柱后引入氢氧化铵增强荧光,在流出液中进行测量(激发波长340纳米,发射波长418纳米)。拉贝洛尔和内标的保留时间分别为1.99分钟和3.32分钟。该药物高、低浓度的日间和日内变异系数均小于7.5%。测定标准曲线在1至250微克/升范围内呈线性。对一些常用的联用药物进行了测试,结果无干扰。