气-液相化学发光法在线测定甲醛气体的研究

Research on the on-line determination of formaldehyde gas by the gas-liquid phase chemiluminescence method.

作者信息

Tan Wenyuan, Chen Qi, Wang Rong, Wang Zhuqing, Zhang Huan, Wu Yuran

机构信息

College of Chemical Engineering, Sichuan University of Science and Engineering Zigong 643000 China

Key Laboratories of Fine Chemicals and Surfactants in Sichuan Provincial Universities Zigong 643000 China.

出版信息

RSC Adv. 2022 Aug 24;12(37):23956-23962. doi: 10.1039/d2ra03175b. eCollection 2022 Aug 22.

Abstract

Based on the gas-liquid phase chemiluminescence tester independently developed by our laboratory, a highly sensitive, fast and accurate on-line detection method of formaldehyde gas in ambient atmosphere is established. The chemiluminescence system and the trace formaldehyde gas in the air directly undergo an interface heterogeneous chemiluminescence reaction to obtain a strong chemiluminescence signal. Through the measurement of the chemiluminescence signal intensity, a highly sensitive, real-time and on-line method for the determination of formaldehyde in the air was established. Factors influencing the experimental results such as gallic acid, potassium dichromate, reaction medium concentration, surfactant type and concentration, pump speed, tube length, and interfering gas were discussed based on the single factor and orthogonal analysis results. Finally, the optimal detection conditions were collected, and the detection results were compared with the national standard phenol reagent method. The results show that when the concentration of the standard formaldehyde gas is in the range of 0-0.582 μg L, the linear equation of this method is = 208 + 29.667, the linear coefficient is = 0.997, and the minimum detection concentration of formaldehyde is 2.327 × 10 μg L. Under the same external conditions, the comparison and analysis using the national standard phenol reagent method proved that this method has the advantages of fast detection speed, low detection limit, good sensitivity, and accurate results, which can be used for real-time and online determination of trace formaldehyde in ambient air.

摘要

基于本实验室自主研发的气液相化学发光测试仪,建立了一种高灵敏、快速、准确的环境大气中甲醛气体在线检测方法。化学发光体系与空气中痕量甲醛气体直接发生界面异相化学发光反应,获得较强的化学发光信号。通过测定化学发光信号强度,建立了一种高灵敏、实时、在线测定空气中甲醛的方法。基于单因素和正交分析结果,讨论了没食子酸、重铬酸钾、反应介质浓度、表面活性剂类型和浓度、泵速、管路长度以及干扰气体等对实验结果的影响因素。最后汇总了最佳检测条件,并将检测结果与国家标准酚试剂法进行了比较。结果表明,当标准甲醛气体浓度在0~0.582μg/L范围内时,该方法的线性方程为=208+29.667,线性系数为=0.997,甲醛最低检测浓度为2.327×10μg/L。在相同外部条件下,采用国家标准酚试剂法进行对比分析,结果表明该方法具有检测速度快、检测限低、灵敏度好、结果准确等优点,可用于环境空气中痕量甲醛的实时在线测定。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/65e6/9400167/68d2bdb2f398/d2ra03175b-f1.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验