Suppr超能文献

[24小时心电图监测与标准化操作在糖尿病患者心脏自主神经病变检测与探查中的比较价值]

[Comparative value of 24-hour ECG monitoring and standardized maneuvers in the detection and exploration of cardiac autonomic neuropathy in diabetics].

作者信息

Valensi P, Attali J R, Sachs R N, Leroy P, Palsky D, Lanfranchi J, Sebaoun J

出版信息

Diabete Metab. 1987 Jun;13(3):205-9.

PMID:3609422
Abstract

24-hour continuous electrocardiographic ECG monitoring and standardized tests were performed to detect cardiac autonomic neuropathy in diabetic patients. Thirty-eight patients, with a mean duration of diabetes of 10 years, twenty-five IDDM and thirteen NIDDM, and thirty-two controls, with no illness or treatment which could alter the heart rate (HR), were studied. Five standardized tests were performed. Three tests investigated parasympathetic function: variations of HR during Valsalva manoeuvre, deep breathing and standing. The other two tests investigated sympathetic function: detection of orthostatic hypotension and blood pressure response to sustained handgrip. Parasympathetic HR control was impaired in twenty-nine patients, together with impaired sympathetic cardiovascular control in seven. According to the 6 indices studied, 24-hour ECG monitoring detected abnormalities in only eight patients. Mean minimum 24-hour HR and mean sleeping HR were elevated in the group of patients whose five standardized tests were normal and in the group of patients with impairment of both parasympathetic and sympathetic cardiovascular control, but not in the group of patients with only impaired parasympathetic HR control. This study suggests that 24-hour ECG monitoring is a less sensitive test of cardiac autonomic neuropathy than standardized tests. Moreover, it shows HR abnormalities that are not specific to cardiac autonomic neuropathy.

摘要

对糖尿病患者进行24小时连续心电图(ECG)监测和标准化测试,以检测心脏自主神经病变。研究了38例糖尿病患者,平均病程10年,其中25例为胰岛素依赖型糖尿病(IDDM),13例为非胰岛素依赖型糖尿病(NIDDM),以及32名对照者,这些对照者无任何可能改变心率(HR)的疾病或治疗。进行了五项标准化测试。三项测试研究副交感神经功能:valsalva动作、深呼吸和站立时心率的变化。另外两项测试研究交感神经功能:检测直立性低血压和持续握力时的血压反应。29例患者副交感神经心率控制受损,7例患者交感神经心血管控制受损。根据所研究的6项指标,24小时心电图监测仅在8例患者中检测到异常。五项标准化测试正常的患者组以及副交感神经和交感神经心血管控制均受损的患者组的平均24小时最低心率和平均睡眠心率升高,但仅副交感神经心率控制受损的患者组未升高。这项研究表明,24小时心电图监测对心脏自主神经病变的检测不如标准化测试敏感。此外,它显示出的心率异常并非心脏自主神经病变所特有。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验