Suppr超能文献

采用新型支架取栓辅助技术取出 Marathon Microcatheter 断裂并嵌顿于 Onyx 中的部分。

Retrieval of a Fractured Marathon Microcatheter Entrapped in Onyx Using a Novel Stentriever-Assisted Technique.

机构信息

Department of Neurosurgery, Royal North Shore Hospital, Sydney, Australia.

出版信息

Oper Neurosurg (Hagerstown). 2022 Oct 1;23(4):e304-e308. doi: 10.1227/ons.0000000000000305. Epub 2022 Jun 14.

Abstract

BACKGROUND AND IMPORTANCE

Endovascular embolization using Onyx has been a major advancement in the treatment of cerebrovascular malformations. Microcatheter entrapment in Onyx is a procedural complication which can pose a thromboembolic risk to patients. There have been 4 retrieval techniques for intact microcatheters entrapped in Onyx previously described in the literature, which are summarized in this report. We present the first case using a novel stentriever-assisted technique to successfully and safely retrieve a fractured microcatheter entrapped in Onyx.

CLINICAL PRESENTATION

An adult patient with a Cognard IIa + b dural arteriovenous fistula (dAVF) underwent Onyx embolization. The microcatheter became entrapped and fractured while initially attempting removal. A stentriever was used off label to capture the fractured microcatheter and then a larger caliber microcatheter was railroaded over it. Retrieval of the fractured microcatheter by the stentriever was then facilitated by counter traction on the Onyx cast using the larger microcatheter.

CONCLUSION

This novel stentriever-assisted technique is a safe and effective rescue maneuver for retrieving a fractured microcatheter trapped in Onyx during embolization of dAVF. There is a need for further research and development of novel devices for retrieval of entrapped microcatheters.

摘要

背景与重要性

使用 Onyx 进行血管内栓塞治疗已成为脑血管畸形治疗的重大进展。Onyx 中微导管的嵌顿是一种程序并发症,可能会给患者带来血栓栓塞风险。文献中之前已经描述了 4 种用于取出完整嵌顿在 Onyx 中的微导管的技术,本报告对此进行了总结。我们报告首例使用新型取栓支架辅助技术成功且安全地取出嵌顿在 Onyx 中的断裂微导管的病例。

临床呈现

一名成人患者患有 Cognard IIa + b 硬脑膜动静脉瘘(dAVF),行 Onyx 栓塞治疗。在最初尝试取出时,微导管被嵌顿并断裂。使用取栓支架超适应证捕获断裂的微导管,然后用更大口径的微导管沿其推送。通过用更大口径的微导管对 Onyx 铸型施加反向牵引力,从而便于取栓支架取出断裂的微导管。

结论

这种新型取栓支架辅助技术是一种安全有效的抢救方法,可用于取出在栓塞 dAVF 过程中嵌顿在 Onyx 中的断裂微导管。需要进一步研究和开发用于取出嵌顿微导管的新型装置。