• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Sequential pulse defibrillation in man: comparison of thresholds in normal subjects and those with cardiac disease.

作者信息

Jones D L, Klein G J, Guiraudon G M, Sharma A D, Kallok M J, Tacker W A, Bourland J D

出版信息

Med Instrum. 1987 Jun;21(3):166-9.

PMID:3614039
Abstract

We compared the parameters describing the defibrillation threshold in patients with normal hearts and in patients with ischemic heart disease, using a special electrode system and sequential pulses of current. Twenty-eight patients consented to the study (mean age: 36.6 +/- 10.1 years; mean mass: 80.7 +/- 13.8 kg). Twenty-one patients underwent surgery for Wolff-Parkinson-White syndrome (relatively normal hearts). Six patients had a history of previous myocardial infarction and aneurysm or coronary artery disease; and one patient had been resuscitated from an episode of sudden death, without evidence of consequent myocardial damage. For 26 patients, defibrillation thresholds were determined intraoperatively by passing sequential pulses through a catheter electrode and epicardial mesh electrode. For 2 patients defibrillation thresholds were determined during electrophysiologic study, after ventricular fibrillation was induced by programmed stimulation, by passing sequential pulses through a catheter and skin-patch electrode. Parameters for sequential pulse defibrillation thresholds between the two groups did not differ appreciably. Total energy for patients with normal hearts averaged 9.9 +/- 6.3 J compared to 8.9 +/- 4.6 J for patients with cardiac disease. No patient with cardiac disease had defibrillation parameters that exceeded the range of the normal patients. These results suggest that the presence of cardiac disease may not significantly alter the parameters necessary for successful defibrillation when using sequential pulses for delivery of energy.

摘要

相似文献

1
Sequential pulse defibrillation in man: comparison of thresholds in normal subjects and those with cardiac disease.
Med Instrum. 1987 Jun;21(3):166-9.
2
Direct comparison of monophasic, biphasic and sequential pulse defibrillation over a single current pathway.在单一电流路径上对单相、双相和序贯脉冲除颤进行直接比较。
Can J Cardiol. 1996 Apr;12(4):407-11.
3
Optimization of epicardial electrode size and implant site for reduced sequential pulse defibrillation thresholds.
Med Instrum. 1986 Jan-Feb;20(1):36-9.
4
Sequential pulse defibrillation in humans: orthogonal sequential pulse defibrillation with epicardial electrodes.人类的序贯脉冲除颤:使用心外膜电极的正交序贯脉冲除颤。
J Am Coll Cardiol. 1988 Mar;11(3):590-6. doi: 10.1016/0735-1097(88)91536-7.
5
Comparison of defibrillation efficacy using implantable cardioverter-defibrillator with single- or dual-coil defibrillation leads and active can.使用带有单线圈或双线圈除颤导线及主动式除颤罐的植入式心律转复除颤器进行除颤效果的比较。
Kardiol Pol. 2005 Sep;63(3):234-41; discussion 242-3.
6
BIPHASIC Trial: a randomized comparison of fixed lower versus escalating higher energy levels for defibrillation in out-of-hospital cardiac arrest.双相波试验:院外心脏骤停时固定较低能量与递增较高能量水平除颤的随机对照比较。
Circulation. 2007 Mar 27;115(12):1511-7. doi: 10.1161/CIRCULATIONAHA.106.648204. Epub 2007 Mar 12.
7
Intraoperative comparison of sequential-pulse and single-pulse defibrillation in candidates for automatic implantable defibrillators.
Am J Cardiol. 1987 Sep 1;60(7):618-24. doi: 10.1016/0002-9149(87)90316-x.
8
[The implantable cardioverter-defibrillator: the Portuguese experience].[植入式心脏复律除颤器:葡萄牙的经验]
Rev Port Cardiol. 1997 Apr;16(4):367-74, 351-2.
9
Effects of shock polarity reversal on defibrillation threshold in an implantable cardioverter-defibrillator.植入式心脏复律除颤器中电击极性反转对除颤阈值的影响。
Kardiol Pol. 2007 May;65(5):495-500; discussion 501-2.
10
Internal cardiac defibrillation: single and sequential pulses and a variety of lead orientations.
Pacing Clin Electrophysiol. 1988 May;11(5):583-91. doi: 10.1111/j.1540-8159.1988.tb04554.x.