Hashemi Hassan, Asgari Soheila
Noor Ophthalmology Research Center, Noor Eye Hospital, Tehran, Iran.
Front Med (Lausanne). 2022 Sep 16;9:985928. doi: 10.3389/fmed.2022.985928. eCollection 2022.
To determine the reference range of corneal indices in Down syndrome patients with normal corneas (DS-N) and to compare it with the corneal indices in Down syndrome patients with keratoconic corneas (DS-KC).
A study was conducted using the data of 154 eyes of 154 DS-N and 25 eyes of 25 DS-KC patients. Eighteen indices related to thickness, anterior chamber, keratometry, elevation, and aberrations routinely used for KC diagnosis were extracted from the Pentacam.
The mean age of the participants in DS-N and DS-KC groups was 16.73 ± 4.70 and 16.56 ± 4.22 years ( = 0.852). In the DS-N group, 95% CI were 511.65-520.31 for minimum corneal thickness, 2.97-3.07 for anterior chamber depth (ACD), 46.83-47.37 for maximum keratometry (Kmax), 46.13-46.62 for zonal Kmax at 3 mm, 0.35-0.58 for inferior-superior asymmetry (I-S value), 1.56-1.88 for Belin/Ambrósio display-total deviation, 8.65-10.79 for best-fit-sphere posterior elevation at the thinnest point, and 0.18-0.22 for corneal vertical coma. The age-related change in I-S value and corneal spherical aberration (SA) was significant (both < 0.05). There were significant inter-gender differences in 11 indices; the female DS patients had shallower, steeper, more elevated, and more aberrated corneas (all < 0.05). There were significant differences in all indices except for ACD ( = 0.372) and corneal SA ( = 0.169) between DS-N and DS-KC groups.
In DS patients aged 10-30 years, the reference ranges of corneal indices are different from the range reported for non-DS subjects and are close to values reported for mild KC non-DS cases. The normal values are different between DS male and female; hence, sex-specific ranges should be considered for diagnosis of corneal abnormality in DS patients.
确定角膜正常的唐氏综合征患者(DS-N)的角膜指数参考范围,并将其与圆锥角膜唐氏综合征患者(DS-KC)的角膜指数进行比较。
使用154例DS-N患者的154只眼和25例DS-KC患者的25只眼的数据进行研究。从Pentacam中提取了18个与厚度、前房、角膜曲率测量、高度和像差相关的指数,这些指数常用于圆锥角膜诊断。
DS-N组和DS-KC组参与者的平均年龄分别为16.73±4.70岁和16.56±4.22岁(P = 0.852)。在DS-N组中,最小角膜厚度的95%置信区间为511.65 - 520.31,前房深度(ACD)为2.97 - 3.07,最大角膜曲率(Kmax)为46.83 - 47.37,3mm处的区域Kmax为46.13 - 46.62,上下不对称性(I-S值)为0.35 - 0.58,Belin/Ambrósio显示总偏差为1.56 - 1.88,最薄点处的最佳拟合球后表面高度为8.65 - 10.79,角膜垂直彗差为0.18 - 0.22。I-S值和角膜球差(SA)的年龄相关性变化具有显著性(均P < 0.05)。11个指数存在显著的性别差异;女性DS患者的角膜更浅、更陡、更高且像差更大(均P < 0.05)。DS-N组和DS-KC组之间,除ACD(P = 0.372)和角膜SA(P = 0.169)外,所有指数均存在显著差异。
在10 - 30岁的DS患者中,角膜指数参考范围与非DS受试者报告的范围不同,且接近轻度圆锥角膜非DS病例报告的值。DS男性和女性的正常值不同;因此,在诊断DS患者的角膜异常时应考虑性别特异性范围。