Suppr超能文献

最大冠状动脉血流储备的测量:一种评估人类冠状动脉病变生理意义的技术。

Measurement of maximal coronary flow reserve: a technique for assessing the physiologic significance of coronary arterial lesions in humans.

作者信息

Wilson R F, White C W

出版信息

Herz. 1987 Jun;12(3):163-76.

PMID:3623398
Abstract

Recent studies suggest that angiographic measurements of coronary arterial stenosis are poorly correlated with direct measurements of the capacity of the artery to conduct hyperemic blood flow. Direct measurement of coronary blood flow and the flow reserve capacity of individual coronary vessels in conscious humans, however, has been hampered by methodologic limitations. We have developed and validated a coronary Doppler catheter capable of subselectively measuring coronary blood flow velocity at the time of cardiac catheterization. Studies in seven calves demonstrated that measurements of the change in coronary blood flow velocity assessed using the Doppler catheter were highly correlated with simultaneous measurements of the change in coronary sinus blood flow (r = 0.97, slope = 1.06) and changes in blood flow velocity assessed using an epicardial Doppler probe (r = 0.95, slope = 1.04). Additional studies demonstrated that the catheter did not produce physiologically significant obstruction to coronary blood flow. Subsequent studies in 215 humans undergoing catheterization have shown that acceptable signals of phasic coronary blood flow velocity could be recorded in 176 patients. Subsequent dose response kinetic studies demonstrated that intracoronary administration of papaverine can rapidly produce maximal coronary hyperemia, equivalent in magnitude to intravenous dipyridamole, but short enough in duration to permit multiple measurements of coronary flow reserve during a single catheterization. Measurements of coronary flow reserve in patients with obstructive coronary artery disease have permitted characterization of the physiologic significance of individual obstructive coronary lesions. The development of this coronary Doppler catheter system and technique for measurement of maximal coronary flow reserve should facilitate characterization of the physiologic impact of coronary arterial lesions on coronary blood flow and studies of the coronary circulation in conscious humans.

摘要

近期研究表明,冠状动脉狭窄的血管造影测量结果与动脉传导充血血流能力的直接测量结果相关性较差。然而,在清醒人体中直接测量冠状动脉血流及各支冠状动脉的血流储备能力一直受到方法学限制的阻碍。我们研发并验证了一种冠状动脉多普勒导管,它能够在心脏导管插入术时选择性地测量冠状动脉血流速度。对7头小牛的研究表明,使用多普勒导管评估的冠状动脉血流速度变化测量值与同时测量的冠状窦血流变化高度相关(r = 0.97,斜率 = 1.06),且与使用心外膜多普勒探头评估的血流速度变化高度相关(r = 0.95,斜率 = 1.04)。进一步研究表明,该导管不会对冠状动脉血流造成具有生理意义的阻塞。随后对215例接受导管插入术的患者进行的研究显示,176例患者能够记录到可接受的心相性冠状动脉血流速度信号。随后的剂量反应动力学研究表明,冠状动脉内注射罂粟碱可迅速产生最大程度的冠状动脉充血,其程度与静脉注射双嘧达莫相当,但持续时间足够短,可在单次导管插入术中对冠状动脉血流储备进行多次测量。对患有阻塞性冠状动脉疾病患者的冠状动脉血流储备测量,有助于明确各个阻塞性冠状动脉病变的生理意义。这种冠状动脉多普勒导管系统及测量最大冠状动脉血流储备技术的开发,应有助于明确冠状动脉病变对冠状动脉血流的生理影响,并有助于开展清醒人体冠状动脉循环的研究。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验