Anand V K, Herbert J, Robbett W F, Zelman W H
Lasers Surg Med. 1987;7(3):275-7. doi: 10.1002/lsm.1900070312.
Anesthesia safety for endoscopic laryngeal laser surgery has been a major limiting factor for laser applications in the larynx and the hypopharynx. Several anesthesia techniques have been proposed and each technique appears to have its own limitations. This paper will deal with the distinct advantages offered by the malleable copper tube which is used for delivery of the open Venturi system anesthesia for endoscopic laser surgery. A retrospective study of 100 patients who have undergone this modality of anesthesia at our institution will be presented. Our conclusion from this study shows clearly the superiority of the copper tube over the conventional aluminium-foil-wrapped endotracheal tube in safety and the exposure of the larynx during surgery.
内镜喉激光手术的麻醉安全性一直是激光在喉部和下咽应用的主要限制因素。已经提出了几种麻醉技术,且每种技术似乎都有其自身的局限性。本文将探讨可塑铜管在为内镜激光手术提供开放式文丘里系统麻醉方面所具有的独特优势。将呈现一项对在我们机构接受这种麻醉方式的100例患者的回顾性研究。我们从这项研究中得出的结论清楚地表明,在安全性以及手术过程中喉部的暴露方面,铜管优于传统的铝箔包裹气管导管。