Massachusetts Eye and Ear, Boston, MA, USA.
Department of Ophthalmology, Harvard Medical School, Boston, MA, USA.
Transl Vis Sci Technol. 2022 Oct 3;11(10):34. doi: 10.1167/tvst.11.10.34.
To determine the feasibility of a custom frame generation approach for nonsurgical management of severe blepharoptosis with the magnetic levator prosthesis (MLP).
Participants (n = 8) with severe blepharoptosis (obscuring the visual axis) in one or both eyes who had previously been using a non-custom MLP had a craniofacial scan with a smartphone app to generate a custom MLP frame. A magnetic adhesive was attached to the affected eyelid. The custom MLP frame held a cylindrical magnet near the eyebrow above the affected eyelid, suspending it in the magnetic field while still allowing blinking. The spectacle magnet could be rotated manually, providing adjustable force via angular translation of the magnetic field. Fitting success and comfort were recorded, and interpalpebral fissure (IPF) was measured from video frames after 20 minutes in-office and one-week at-home use. Preference was documented, custom versus non-custom.
Overall, 88% of patients (7/8) were successfully fitted with a median 9/10 comfort (interquartile 7-10) and median ptosis improvement of 2.3 mm (1.3-5.0); P = 0.01). Exact binomial testing suggested, with 80% power, that the true population success rate was significantly greater than 45% (P = 0.05). Five participants took the custom MLP home for one week, with only one case of mild conjunctival redness which resolved without treatment. Highest to lowest force modulation resulted in a marginally significant median IPF adjustment of 1.5 mm (0.8 to 2.7; P = 0.06). All preferred the custom frame.
The three-dimensional custom MLP frame generation approach using a smartphone app-based craniofacial scan is a feasible approach for clinical deployment of the MLP.
First demonstration of customized frame generation for the MLP.
确定使用磁提举假体(MLP)对严重上睑下垂进行非手术管理的定制框架生成方法的可行性。
参与者(n=8)在一只或两只眼睛患有严重上睑下垂(遮挡视线),此前使用非定制 MLP,通过智能手机应用程序进行颅面扫描以生成定制 MLP 框架。在受影响的眼睑上贴上磁性粘合剂。定制的 MLP 框架在受影响的眼睑上方的眉毛附近放置一个圆柱形磁铁,在磁场中悬挂它,同时仍允许眨眼。可以手动旋转眼镜磁铁,通过磁场的角位移提供可调节的力。记录了适配成功和舒适度,并在办公室 20 分钟和在家一周后从视频帧中测量了睑裂(IPF)。记录了偏好,定制与非定制。
总体而言,88%的患者(7/8)成功适配,中位数舒适度为 9/10(四分位距 7-10),上睑下垂改善中位数为 2.3 毫米(1.3-5.0);P=0.01)。精确二项式检验表明,在 80%的功率下,真实人群的成功率显著大于 45%(P=0.05)。5 名参与者将定制的 MLP 带回家一周,只有 1 例轻度结膜发红,未经治疗即可自行消退。最高到最低的力调节导致中位 IPF 调整略有显著,为 1.5 毫米(0.8 至 2.7;P=0.06)。所有参与者都更喜欢定制框架。
使用基于智能手机应用程序的颅面扫描的三维定制 MLP 框架生成方法是 MLP 临床部署的可行方法。
杨爽