Suppr超能文献

一种用于完全自动眨眼的磁驱动器设备:在人类参与者中的首个概念验证。

A Magnetic Actuator Device for Fully Automated Blinking in Total Bidirectional Eyelid Paralysis: First Proof of Concept in a Human Participant.

机构信息

Departments of Neurology and Ophthalmology, University of Massachusetts Chan Medical School, Worcester, MA, USA.

Department of Neurology, University of Massachusetts Chan Medical School, Worcester, MA, USA.

出版信息

Transl Vis Sci Technol. 2024 May 1;13(5):2. doi: 10.1167/tvst.13.5.2.

Abstract

PURPOSE

Currently, no solution exists to restore natural eyelid kinematics for patients with complete eyelid paralysis due to loss of function of both the levator palpebrae superioris and orbicularis oculi. These rare cases are prone to complications of chronic exposure keratopathy which may lead to corneal blindness. We hypothesized that magnetic force could be used to fully automate eyelid movement in these cases through the use of eyelid-attached magnets and a spectacle-mounted magnet driven by a programmable motor (motorized magnetic levator prosthesis [MMLP]).

METHODS

To test this hypothesis and establish proof of concept, we performed a finite element analysis (FEA) for a prototype MMLP to check the eyelid-opening force generated by the device and verified the results with experimental measurements in a volunteer with total bidirectional eyelid paralysis. The subject was then fitted with a prototype to check the performance of the device and its success.

RESULTS

With MMLP, eye opening was restored to near normal, and blinking was fully automated in close synchrony with the motor-driven polarity reversal, with full closure on the blink. The device was well tolerated, and the participant was pleased with the comfort and performance.

CONCLUSIONS

FEA simulation results conformed to the experimentally observed trend, further supporting the proof of concept and design parameters. This is the first viable approach in human patients with proof of concept for complete reanimation of a bidirectionally paretic eyelid. Further study is warranted to refine the prototype and determine the feasibility and safety of prolonged use.

TRANSLATIONAL RELEVANCE

This is first proof of concept for our device for total bidirectional eyelid paralysis.

摘要

目的

由于提上睑肌和眼轮匝肌功能丧失,完全性眼睑瘫痪的患者目前尚无恢复自然眼睑运动的方法。这些罕见病例容易发生慢性暴露性角膜病变的并发症,可能导致角膜失明。我们假设可以通过使用眼睑附着磁铁和由可编程电机驱动的眼镜安装磁铁(电动磁提上睑肌假体 [MMLP])来充分实现这些情况下的眼睑自动运动。

方法

为了验证这一假设并建立概念验证,我们对原型 MMLP 进行了有限元分析(FEA),以检查该装置产生的眼睑张开力,并通过对一位总双向眼睑瘫痪的志愿者进行实验测量来验证结果。然后,该受试者被安装了一个原型来检查设备的性能及其成功情况。

结果

使用 MMLP,眼睛睁开恢复到接近正常,眨眼完全自动与电机驱动的极性反转同步,眨眼时完全闭合。该设备耐受性良好,参与者对舒适度和性能感到满意。

结论

FEA 模拟结果与实验观察到的趋势一致,进一步支持了概念验证和设计参数。这是在有双向瘫痪的人类患者中首次可行的方法,证明了完全重新激活双向瘫痪眼睑的概念验证。需要进一步研究来改进原型,并确定长期使用的可行性和安全性。

翻译

Chen Liang

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/bb2e/11077920/b6cdd9300851/tvst-13-5-2-f001.jpg