Suspected intracardiac masses: evaluation with MR imaging.

作者信息

Winkler M, Higgins C B

出版信息

Radiology. 1987 Oct;165(1):117-22. doi: 10.1148/radiology.165.1.3628757.

Abstract

Electrocardiographically gated magnetic resonance (MR) imaging was used to examine 34 patients believed or known to have intracardiac masses on the basis of results from two-dimensional (2D) echocardiography. Cardiac masses were confirmed in 15 patients on the basis of MR imaging results. In seven patients, MR imaging confirmed the absence of an intracardiac mass but demonstrated an anatomic variant or other abnormality that had been interpreted as a possible mass on the echocardiogram. In 12 patients, MR demonstrated neither an intracardiac mass nor an anatomic variant that was likely to have been misinterpreted as a mass on the echocardiogram. Clinical follow-up in these patients at 10 months to 2 years and repeat 2D echocardiography have not indicated a definite mass. In six patients tissue characterization of the mass with MR imaging added some specificity to the MR diagnosis. Thus, MR imaging can be used to verify intracardiac masses found on 2D echocardiograms and to exclude a mass as the cause of equivocal findings on 2D echocardiography.

摘要

采用心电图门控磁共振(MR)成像对34例根据二维(2D)超声心动图结果被认为或已知患有心内肿块的患者进行检查。根据MR成像结果,15例患者确诊存在心内肿块。7例患者中,MR成像证实不存在心内肿块,但显示出一种解剖变异或其他异常,这些在超声心动图上曾被解释为可能的肿块。12例患者中,MR既未显示心内肿块,也未显示可能在超声心动图上被误判为肿块的解剖变异。对这些患者进行10个月至2年的临床随访及重复2D超声心动图检查,均未提示存在明确肿块。6例患者通过MR成像对肿块进行组织特征分析,为MR诊断增加了一些特异性。因此,MR成像可用于验证2D超声心动图发现的心内肿块,并排除肿块是2D超声心动图上可疑发现的原因。