Suppr超能文献

巩膜外加压物的移除。

The removal of scleral buckles.

作者信息

Hilton G F, Wallyn R H

出版信息

Arch Ophthalmol. 1978 Nov;96(11):2061-3. doi: 10.1001/archopht.1978.03910060449011.

Abstract

Six hundred consecutive retinal detachments were operated on with silicone scleral buckles. Twenty-three implants, or 3.8%, were removed. There was one solid silicone implant and 22 silicone sponges. Removal was required because of infection (seven eyes), foreign-body sensation without infection (seven eyes), recurrent subconjunctival hemorrhages (four eyes), impingement on the optic nerve (one eye), and distortion of the macula (four eyes). The postoperative infection rate was 1.8% for silicone sponges, and there were no infections in eyes buckled with solid silicone. Only one retina redetached after buckle removal, yielding a recurrence rate of 4%. The one recurrence was successfully managed by a second scleral buckle.

摘要

对连续600例视网膜脱离患者采用硅酮巩膜扣带术进行手术。23个植入物(占3.8%)被取出。其中有1个固体硅酮植入物和22个硅酮海绵。取出的原因包括感染(7只眼)、无感染的异物感(7只眼)、反复性结膜下出血(4只眼)、对视神经的压迫(1只眼)以及黄斑变形(4只眼)。硅酮海绵的术后感染率为1.8%,使用固体硅酮扣带的眼未发生感染。取出扣带后仅1只视网膜再次脱离,复发率为4%。再次通过巩膜扣带术成功处理了这例复发情况。