Suppr超能文献

采用模型和头影测量叠加以研究 Carriere Motion 3D 矫治器的三维效果:回顾性研究

Retrospective investigation of the 3D effects of the Carriere Motion 3D appliance using model and cephalometric superimposition.

机构信息

Department of Orthodontics, Center for Dental and Oral Medicine, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany.

Orthodontic practice, Laizer Straße 1, 72488, Sigmaringen, Germany.

出版信息

Clin Oral Investig. 2023 Feb;27(2):631-643. doi: 10.1007/s00784-022-04768-4. Epub 2022 Nov 10.

Abstract

OBJECTIVES

Carriere Motion 3D™ appliance (CMA) represents a method for molar distalization and correction of class II malocclusion. The aim was to investigate the 3D effects of the CMA by superimposing digital models and cephalometric X-rays.

MATERIALS AND METHODS

We retrospectively examined 16 patients treated with CMA in combination with class II elastics. We compared digitized models and cephalometric X-rays of records taken before therapy and after the removal of CMA. The records were superimposed to assess the skeletal and dentoalveolar changes. The results of the cephalometric X-ray analysis were compared to an untreated age- and gender-matched sample.

RESULTS

Class II occlusion was corrected after 11.85 ± 4.70 months by 3.45 ± 2.33 mm. The average distalization of the upper first molars was 0.96 ± 0.80 mm. The analysis of the cephalometric X-rays confirmed a distalization of the upper first molars with distal tipping and revealed a mesialization of the lower first molars of 1.91 ± 1.72 mm. Importantly, CMA resulted in a mild correction of the skeletal class II relationship (ANB: - 0.71 ± 0.77°; Wits: - 1.99 ± 1.74 mm) and a protrusion of the lower incisors (2.94 ± 2.52°). Compared to the untreated control group, there was significant distalization of the upper first molars and canines with mesialization and extrusion of the lower first molars.

CONCLUSION AND CLINICAL RELEVANCE

CMA is an efficient method for treating class II malocclusions. However, the class II correction is only partially caused by a distalization of the upper molars.

摘要

目的

Carriere Motion 3D™ 矫治器(CMA)代表了一种远移磨牙和矫正 II 类错颌的方法。本研究旨在通过叠加数字模型和头颅侧位 X 光片来探讨 CMA 的 3D 效果。

材料和方法

我们回顾性地检查了 16 例接受 CMA 联合 II 类橡皮圈治疗的患者。我们比较了治疗前和 CMA 拆除后的数字化模型和头颅侧位 X 光片记录。通过重叠记录来评估骨骼和牙颌的变化。将头影测量 X 光分析的结果与未经治疗的年龄和性别匹配的样本进行比较。

结果

11.85±4.70 个月后,II 类错合得到矫正,矫正值为 3.45±2.33mm。上颌第一磨牙的平均远移量为 0.96±0.80mm。头影测量 X 光分析证实上颌第一磨牙远移并伴有远中倾斜,下颌第一磨牙近中移动 1.91±1.72mm。重要的是,CMA 导致了骨骼 II 类关系的轻度矫正(ANB:-0.71±0.77°;Wits:-1.99±1.74mm)和下颌切牙的突出(2.94±2.52°)。与未经治疗的对照组相比,上颌第一磨牙和尖牙明显远移,下颌第一磨牙近中移动并外展。

结论和临床相关性

CMA 是治疗 II 类错颌的有效方法。然而,II 类矫正的部分原因是上颌磨牙的远移。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/7202/9889508/9fb93b29cf22/784_2022_4768_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验