基于双能计算机断层扫描的碘浓度估计用于评估脉络膜恶性黑色素瘤的治疗反应:优化与初步验证

Dual-Energy Computed Tomography-Based Iodine Concentration Estimation for Evaluating Choroidal Malignant Melanoma Response to Treatment: Optimization and Primary Validation.

作者信息

Tsuchiya Hiroki, Tachibana Yasuhiko, Kishimoto Riwa, Omatsu Tokuhiko, Hotta Eika, Tanimoto Katsuyuki, Wakatsuki Masaru, Obata Takayuki, Tsuji Hiroshi

机构信息

Radiological Technology Section, Department of Medical Technology, QST Hospital, Chiba 263-8555, Japan.

Quantum-Medicine AI Research Group, National Institutes for Quantum Science and Technology (QST), Chiba 263-8555, Japan.

出版信息

Diagnostics (Basel). 2022 Nov 4;12(11):2692. doi: 10.3390/diagnostics12112692.

Abstract

Contrast-enhanced imaging for choroidal malignant melanoma (CMM) is mostly limited to detecting metastatic tumors, possibly due to difficulties in fixing the eye position. We aimed to (1) validate the appropriateness of estimating iodine concentration based on dual-energy computed tomography (DECT) for CMM and optimize the calculation parameters for estimation, and (2) perform a primary clinical validation by assessing the ability of this technique to show changes in CMM after charged-particle radiation therapy. The accuracy of the optimized estimate (eIC_optimized) was compared to an estimate obtained by commercial software (eIC_commercial) by determining the difference from the ground truth. Then, eIC_optimized, tumor volume, and CT values (80 kVp, 140 kVp, and synthesized 120 kVp) were measured at pre-treatment and 3 months and 1.5−2 years after treatment. The difference from the ground truth was significantly smaller in eIC_optimized than in eIC_commercial (p < 0.01). Tumor volume, CT values, and eIC_optimized all decreased significantly at 1.5−2 years after treatment, but only eIC_commercial showed a significant reduction at 3 months after treatment (p < 0.01). eIC_optimized can quantify contrast enhancement in primary CMM lesions and has high sensitivity for detecting the response to charged-particle radiation therapy, making it potentially useful for treatment monitoring.

摘要

脉络膜恶性黑色素瘤(CMM)的对比增强成像大多局限于检测转移性肿瘤,这可能是由于固定眼球位置存在困难。我们旨在:(1)验证基于双能计算机断层扫描(DECT)估算CMM碘浓度的适宜性并优化估算的计算参数;(2)通过评估该技术显示带电粒子放射治疗后CMM变化的能力进行初步临床验证。通过确定与真实值的差异,将优化估算值(eIC_optimized)的准确性与商业软件获得的估算值(eIC_commercial)进行比较。然后,在治疗前、治疗后3个月以及1.5 - 2年测量eIC_optimized、肿瘤体积和CT值(80 kVp、140 kVp和合成的120 kVp)。eIC_optimized与真实值的差异显著小于eIC_commercial(p < 0.01)。治疗后1.5 - 2年肿瘤体积、CT值和eIC_optimized均显著下降,但仅eIC_commercial在治疗后3个月显示出显著降低(p < 0.01)。eIC_optimized能够量化原发性CMM病变中的对比增强,并且对检测带电粒子放射治疗的反应具有高灵敏度,使其在治疗监测方面具有潜在用途。