Suppr超能文献

初次全髋关节置换术后 30 至 35 年的生存和临床结果:采用全涂层羟基磷灰石的非骨水泥股骨柄。

Survival and Clinical Outcomes at 30 to 35 Years Following Primary Total Hip Arthroplasty With a Cementless Femoral Stem Fully Coated With Hydroxyapatite.

机构信息

Artro Institute, Annecy Le Vieux, France; Clinique d'Argonay, Ramsay Santé, Annecy, France.

Artro Institute, Annecy Le Vieux, France; Centre Orthopédique Santy, Hôpital Privé Jean Mermoz, Ramsay Santé, Lyon, France.

出版信息

J Arthroplasty. 2023 May;38(5):880-885. doi: 10.1016/j.arth.2022.11.016. Epub 2022 Dec 8.

Abstract

BACKGROUND

The purpose of the present study was to update and report clinical outcomes and survival of primary total hip arthroplasty using a cementless double-tapered titanium fully hydroxyapatite-coated stem at a follow-up > 30 years.

METHODS

The outcomes of this series of 347 primary total hip arthroplasties were already published at a follow-up > 25 years, during which only 12 stems were revised. Since then, there were two additional stem revisions, bringing the total to 14 stem revisions (all of which also required cup revision). Patients still living with the original stem were assessed using the modified Harris Hip Score and patient satisfaction (very satisfied, satisfied, dissatisfied, and very dissatisfied). Revision incidence was calculated using the Kaplan-Meier (KM) method and Cumulative Incidence Function (CIF) at 35 years.

RESULTS

At a mean follow-up of 33 years (range, 31 to 35 years), 32 patients (34 hips) were still living with the original stem. Their mean modified Harris Hip Score was 86 points (range, 46 to 100) and all patients (100%) were very satisfied or satisfied with surgery. The revision incidence at 35 years considering (a) stem revision for any reason was 9.5% using KM and 4.5% using CIF; (b) stem revision for aseptic loosening was 3.1% using KM and 2.1% using CIF; and (c) reoperation or revision of any component for any reason was 45.3% using KM and 26.3% using CIF.

CONCLUSION

The present study has demonstrated excellent survival at 35 years for a cementless double-tapered titanium fully hydroxyapatite-coated stem.

LEVEL OF EVIDENCE

Level IV, Retrospective cohort study.

摘要

背景

本研究的目的是更新并报告使用无水泥双锥形钛全羟基磷灰石涂层柄在随访> 30 年后的初次全髋关节置换术的临床结果和生存率。

方法

本系列 347 例初次全髋关节置换术的结果已经在随访> 25 年后发表,在此期间仅进行了 12 例翻修。此后,又有两例翻修,总共进行了 14 例翻修(均需要进行杯体翻修)。仍使用原始柄的患者使用改良 Harris 髋关节评分和患者满意度(非常满意、满意、不满意和非常不满意)进行评估。使用 Kaplan-Meier(KM)法和累积发生率函数(CIF)计算 35 年后的翻修发生率。

结果

平均随访 33 年(范围,31-35 年),32 例患者(34 髋)仍使用原始柄。他们的平均改良 Harris 髋关节评分为 86 分(范围,46-100),所有患者(100%)对手术非常满意或满意。考虑到(a)任何原因的柄翻修,KM 法的 35 年翻修发生率为 9.5%,CIF 法为 4.5%;(b)无菌性松动的柄翻修,KM 法为 3.1%,CIF 法为 2.1%;以及(c)任何原因的任何组件的再手术或翻修,KM 法为 45.3%,CIF 法为 26.3%。

结论

本研究表明,无水泥双锥形钛全羟基磷灰石涂层柄在 35 年时具有优异的生存率。