Suppr超能文献

血流导向支架治疗覆盖眼动脉起源对眼科影像学表现的影响。

Effect on ophthalmic imaging findings of flow-diverting stent treatment covering the origin of the ophthalmic artery.

作者信息

Ökçesiz İzzet, Dönmez Halil, Polat Osman Ahmet, Alpşahin Mehmet, Sönmez Hatice Kübra, Temizyürek Özge

机构信息

Department of Radiology, Erciyes University School of Medicine, Kayseri, Turkiye.

Department of Radiology, Erciyes University School of Medicine, Kayseri, Turkiye.

出版信息

Photodiagnosis Photodyn Ther. 2023 Mar;41:103247. doi: 10.1016/j.pdpdt.2022.103247. Epub 2022 Dec 17.

Abstract

BACKGROUND

Flow-diverting stents are devices that are increasingly used in the treatment of intracranial aneurysms and expand the spectrum of endovascular treatment. The patency of side branches and perforators is a major concern about flow-diverting stent (FDS) treatment.

METHODS

From 2011 to 2020, seventy-eight patients in whom the orifice of the ophthalmic artery was covered during FDS treatment were evaluated in this study. Bilateral retinal vascular parameters of study subjects were evaluated with OCT and OCTA. The FDS implanted-side eyes of the patients were defined as the procedure group, and the fellow eyes were considered as the control group.

RESULTS

Twenty-seven patients who were treated with FDS covering the ostium of the ophthalmic artery and who could undergo full ophthalmologic examination were included in the study. There was no statistically significant difference found in terms of visual acuity, retinal vascular parameters, and choroidal thickness between the procedure group and the control group (p>0.05). However, in one case, recanalized retinal artery branch occlusion was detected on the side where the FDS was implanted.

CONCLUSION

The orifice of the ophthalmic artery is often covered during FDS treatment for carotid-ophthalmic aneurysms; however, this treatment approach has no significant effect on ophthalmic vascular parameters.

摘要

背景

血流导向支架是一种越来越多地用于治疗颅内动脉瘤的装置,它拓宽了血管内治疗的范围。分支血管和穿支血管的通畅性是血流导向支架(FDS)治疗的一个主要关注点。

方法

本研究评估了2011年至2020年间在FDS治疗过程中眼动脉开口被覆盖的78例患者。使用光学相干断层扫描(OCT)和光学相干断层扫描血管造影(OCTA)评估研究对象的双侧视网膜血管参数。将患者植入FDS一侧的眼睛定义为手术组,对侧眼睛作为对照组。

结果

本研究纳入了27例接受FDS覆盖眼动脉开口治疗且能接受全面眼科检查的患者。手术组和对照组在视力、视网膜血管参数和脉络膜厚度方面均未发现统计学上的显著差异(p>0.05)。然而,有1例在植入FDS的一侧检测到视网膜动脉分支再通闭塞。

结论

在对颈眼动脉瘤进行FDS治疗时,眼动脉开口常被覆盖;然而,这种治疗方法对眼部血管参数没有显著影响。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验